Setting Up Parameters
Scaling
A Characteristic Distance and Length must be established to allow the FM-3 to scale user
units back to actual motor revolutions. This scaling factor is as follows:
Characteristic Distance
Scaling =>
Characteristic Length
Characteristic Distance
This is the distance the load travels (in user units) when the motor travels the characteristic
length (in motor revolutions).
Characteristic Length
This is the distance the motor travels (in whole number of revolutions) to achieve one
characteristic distance of load travel.
Distance Scaling Examples
A 1.5" diameter pulley is used to drive a conveyor belt, and the user wishes to use units of
inches instead of revolutions.
Units Name —> Set to Inches
Decimal Places —> Set to desired accuracy 0.000
In one revolution of the motor (or pulley), the belt will travel a distance of one pulley
circumference.
= 1.5" x π
= 1.5 x 3.14...
= 4.712 inches / revolution
Characteristic Distance = 4.712
=>
Characteristic Length = 1
If the user decides to put a 5:1 reducer on the system, they simply need to change the
characteristic length.
Now the belt travels 4.71" in 5 motor revolutions.
Characteristic Distance = 4.712
=>
Characteristic Length = 5