CP200 Series Commercial / Industrial Pressure-
Loaded Pressure Reducing Regulator
Introduction
Scope of the Manual
This manual provides instructions for the installation,
maintenance, and parts ordering information for CP200 Series
pressure loaded pressure reducing regulators.
Figure 1. Typical CP200 Pressure Loaded Pressure Reducing Regulator
P1180
Table of Contents
Introduction ............................................................................ 1
Specifications ........................................................................3
Principle of Operation ............................................................4
Installation and Overpressure Protection ..............................6
Startup ...................................................................................7
Adjustment.............................................................................7
Shutdown...............................................................................7
Maintenance ..........................................................................8
Parts Ordering .......................................................................9
Parts List................................................................................9
Przeglądanie stron 0
1 2 3 4 5 6 ... 11 12

Podsumowanie treści

Strona 1 - CP200 Series

CP200 SeriesD103121X012Instruction ManualForm 5834December 2013www.fisherregulators.comCP200 Series Commercial / Industrial Pressure- Loaded Pressure

Strona 2

CP200 Series10Figure 5. CP200 Series Regulator AssemblyAPPLY LUBRICANT (L) / SEALANT (S)(1) L1 = ANTI-SEIZE LUBRICANT L2 = SILICON GREASE S = THREAD

Strona 3

CP200 Series11L1L225273636L1L22527 APPLY LUBRICANT (L)(1) L1 = ANTI-SEIZE LUBRICANT L2 = SILICON GREASEFigure 6. CP200 Series Diaphragm and Stem As

Strona 4

CP200 Series©Emerson Process Management Regulator Technologies, Inc., 2008, 2013; All Rights ReservedIndustrial RegulatorsEmerson Process Management R

Strona 5

CP200 Series2Table 2. Inlet Pressure Ratings and Flow and Sizing CoefcientsSERIESORIFICE SIZEMAXIMUM OPERATING INLET PRESSURE(1)(2)FLOW COEFFICIENTS

Strona 6

CP200 Series3Available CongurationsType CP200IN - Regulator with internal registrationType CP200IT - Regulator with internal registration and token r

Strona 7

CP200 Series4Principle of OperationRefer to Figure 2. The CP200 Series has spring-to-close construction and uses 67CP Series pressure loading regulat

Strona 8

CP200 Series5CLOSING SPRINGDIAPHRAGMCONTROL SPRINGVALVE STEMLEVERPRESSURE RETAINING PLUG (DO NOT REMOVE)MAIN REGULATORTYPE 67CP PRESSURELOADING REGULA

Strona 9

CP200 Series6Secondary Seat™ Protection does not provide additional overpressure protection in the event the secondary seat or disk is damaged by debr

Strona 10

CP200 Series7• Install the regulator with the vent pointed vertically down, see Figure 4. If the vent cannot be installed in a vertically down posit

Strona 11

CP200 Series8Maintenance!WARNINGTo avoid personal injury or equipment damage, do not attempt any maintenance or disassembly without rst isolating the

Strona 12

CP200 Series92. Inspect the removed parts for damage and debris. Replace any damaged parts.3. To remove the valve cartridge assembly, grasp the end