MonitoringFor Business-Critical Continuity™Liebert® IntelliSlot® Web CardsInstallation Manual – Liebert IntelliSlot Web Card, Liebert IntelliSlot Web
Configuration Overview63.0 CONFIGURATION OVERVIEWYou may use any of the following interfaces to configure the Web card: Each configuration section pro
Configuration Overview73.2 Open the Terminal Emulation Interface - Serial ConnectionTo access configuration using terminal emulation software with a s
Configuration Overview83.3 Open the Terminal Emulation Interface - TCP/IP ConnectionTo access configuration using terminal emulation software with an
Configuration Overview93.4 Open the Telnet InterfaceTo access configuration using Telnet:1. Open a Telnet connection on a computer with an Ethernet co
Configuration Overview103.5 Open the Web InterfaceTo access configuration using the Web interface:1. Open a Web browser such as Internet Explorer, the
System Information114.0 SYSTEM INFORMATIONSystem Information is optional and identifies the Liebert unit, its location, a contact person and other inf
Network Settings125.0 NETWORK SETTINGSThe IP Network Settings Menu is used to enable network communications with the Web card.Refer to the following s
Network Settings135.1 Boot/IP SettingsThe Boot/IP Settings Menu is used to set parameters for network access to the Web card. Consult your network adm
Network Settings145.2 Domain Name Server (DNS) SettingsThe Domain Name Server settings menu configures the servers the Web card will use for hostname
Network Settings15Web InterfaceTo access the DNS menu through the Web interface:• Click on the Configure tab, then Network Settings in the left panel
Network Settings16Web InterfaceTo access Management Protocol settings through the Web interface: • Click on the Configure tab, then Management Protoco
Network Settings17SNMP Communications MenuUse the SNMP Communications Menu to enable authentication traps and view or change communi-ties and trap com
Network Settings18Display/Modify Trap CommunitiesView devices that are configured to receive notifications from the Web card, identified by IP address
Network Settings195.4 Web ServerUse the Web Server Menu to configure access to the card through the Web interface. Consult your network adminis-trator
Network Settings205.4.2 Install Security Certificates - Internet Explorer 6 or earlierIf you use Internet Explorer 6 or an earlier version and select
Network Settings21• In the Certificate window, click the Install Certificate button, as shown below.• The Certificate Import Wizard opens. Click Next.
Network Settings225.4.3 Install Security Certificates - Internet Explorer 7 or laterIf you use Internet Explorer 7 or later and select HTTPS as the op
Network Settings23• In the Certificate window, click the Install Certificate button, as shown below.• The Certificate Import Wizard opens. Click Next.
Network Settings245.5 Telnet ServerUse the Telnet Server Menu to enable or disable access to the Web card through a Telnet interface.Terminal Emulatio
Network Settings25Terminal Emulation (Serial or TCP/IP Connection) / TelnetTo change this setting:1. Choose IP Network Settings from the Main Menu, th
iTABLE OF CONTENTSIMPORTANT SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11.0 IN
Network Settings265.7 Change Username / PasswordThe Web card is designed for two types of access, each with a default user name and password. For secu
Network Settings275.8 Reset Authentication to Factory DefaultsYou may reset the Administrator and General User usernames and passwords to the factory
Messaging286.0 MESSAGINGThe Messaging menu is used to set up e-mail and text message notifications from the Web card.Terminal Emulation (Serial or TCP
Messaging296.1 E-Mail ConfigurationSetting up event notifications to be sent via e-mail involves two steps: enabling the function, then specifying the
Messaging30Web InterfaceTo access E-Mail Configuration through the Web interface:• Click on the Configure tab, then Email in the left panel and finall
Messaging31Terminal Emulation (Serial or TCP/IP Connection) / TelnetTo activate and set up SMS messages:1. Choose Messaging from the Main Menu, then S
Messaging326.3 Customize MessagesBoth e-mail and SMS text messages may be custom-ized to include items such as the IP address or host-name, event name
Messaging33Web InterfaceTo access Customize Message settings through the Web interface:• Click on the Configure tab, then Customize Messages in the le
Factory Settings347.0 FACTORY SETTINGSFactory default values may be restored for all configuration settings. This step:• Replaces all user-defined set
Factory Settings357.2 Liebert DS - Local Node Settings for Multiple CardsIf you use two cards of the same type with the Liebert DS, you will need to c
ii9.0 SUPPORT INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .399.1 View Web Card Infor
Monitor and Control Functions - Web Only368.0 MONITOR AND CONTROL FUNCTIONS - WEB ONLYWeb Interface OnlyThe Web interface allows you to monitor and co
Monitor and Control Functions - Web Only378.2 Controlling Liebert EquipmentTo perform Control operations through the Web interface:• Open the Web inte
Monitor and Control Functions - Web Only388.3 Event LogThe Event Log tab allows viewing events stored in the Web card’s history. This history is gathe
Support Information399.0 SUPPORT INFORMATIONSupport data includes identifying information for the Web card, as well as events and parameters available
Support Information409.2 Events and ParametersYou may view a list of all supported events and parameters for the Liebert equipment through any interfa
IntroductionA1APPENDIX A-FIRMWARE UPDATESA.1 INTRODUCTIONLiebert’s IntelliSlot® cards may be updated to take advantage of the latest release of the fi
Connect to the Card - Terminal Emulation, Telnet or Web InterfaceA2A.2 CONNECT TO THE CARD - TERMINAL EMULATION, TELNET OR WEB INTERFACEUpgrading the
Preparing to Update Liebert IntelliSlot FirmwareA3A.2.3 Open the Telnet InterfaceTo connect to the card using Telnet:1. Open a Telnet connection on a
Preparing to Update Liebert IntelliSlot FirmwareA4A.3.2 Determine the Liebert IntelliSlot Card Type and Firmware VersionEach type of Liebert IntelliSl
Updating the Firmware - HTTP (Web) MethodA5A.3.4 Choose a Method to Install the Firmware UpgradeTo install the firmware upgrade, choose one of these t
1IMPORTANT SAFETY INSTRUCTIONSSAVE THESE INSTRUCTIONS!WARNINGOnly a qualified service professional should install these products. Liebert recommends h
Updating the Firmware - TFTP (HyperTerminal, Telnet, Web) MethodA6A.5 UPDATING THE FIRMWARE - TFTP (HYPERTERMINAL, TELNET, WEB) METHODFollow these ste
Updating the Firmware - TFTP (HyperTerminal, Telnet, Web) MethodA7Begin the Upgrade Process11. When ready to begin the update, choose Initiate TFTP Fi
Updating the Firmware - TFTP (HyperTerminal, Telnet, Web) MethodA8Specify TFTP Server and Upgrade Filename4. Click the Edit button in the right panel.
Updating the Firmware - Xmodem (Serial) MethodA911. During the update, the window displays a progress bar, as shown below left.After the firmware upda
Updating the Firmware - Xmodem (Serial) MethodA10Connect a Cable to the Serial Ports1. Connect one end of a DB-9 null modem or file transfer cable to
Updating the Firmware - Xmodem (Serial) MethodA11Download the First Firmware Update File12. After changing the communication rate to 115200 bps, press
Updating the Firmware - Xmodem (Serial) MethodA12Complete the Upgrade and Restore Communication Rate22. Choose 9600 bps from the menu, shown below lef
Updating the Firmware - Xmodem (Serial) MethodA13Notes
Updating the Firmware - Xmodem (Serial) MethodA14
Introduction21.0 INTRODUCTIONThe Liebert® IntelliSlot® Web Card family delivers enhanced communications and control to Liebert AC Power and Precision
Ensuring The High AvailabilityOf Mission-Critical Data And Applications.Emerson Network Power, the global leader in enabling business-criticalcontinui
Introduction31.2 Web SupportThe Liebert IntelliSlot Web card delivers Web management and control to Liebert equipment. All authorized users on your ne
Installation42.0 INSTALLATION2.1 Install a Liebert IntelliSlot Web Card—Non-Adapter VersionFollow these steps to install a Liebert IntelliSlot Web car
Installation52.2 Install a Liebert IntelliSlot Web/485 Card With AdapterFollow these steps to install a Liebert IntelliSlot Web/485 Card With Adapter