www.Fisher.com
Fisher
FIELDVUE
DVC2000 Digital Valve
Controller
Quick Start Guide
D103203X012
DVC2000 Digital Valve Controller
April 2014
Note
This guide provides installation, initial setup, and calibration information for the DVC2000 digital valve controller. See the
FIELDVUE DVC2000 Digital Valve Controller Instruction Manual (D103176X012), available from your Emerson Process
Management sales office, for additional information, or visit our website at www.FIELDVUE.com.
Instrument Level
Device Type
Device Revision
Hardware Revision
Firmware Revision
DD Revision
Contents
Using this Guide 4..............................
Installation 5..................................
Basic Setup and Calibration 18....................
Specifications 29...............................
Related Documents 32..........................
Hazardous Area Approvals and Special Instructions
Instructions for “Safe Use”and Installations
in Hazardous Locations 33.....................
HC, AD, PD
5
1
1 & 2
1, 2, 3, 4 & 5
3
W8861
AC
5
1
1 & 2
1, 2, 3, 4 & 5
1
Przeglądanie stron 0
1 2 3 4 5 6 ... 39 40

Podsumowanie treści

Strona 1 - Controller

www.Fisher.comFisher FIELDVUE™ DVC2000 Digital ValveControllerQuick Start GuideD103203X012DVC2000 Digital Valve ControllerApril 2014NoteThis guide pr

Strona 2 - Local Interface Flow Chart

Quick Start GuideD103203X012DVC2000 Digital Valve ControllerApril 201410Mounting on GX ActuatorsThe DVC2000 digital valve controller mounts directly o

Strona 3

Quick Start GuideD103203X012DVC2000 Digital Valve ControllerApril 201411If the process and ambient temperatures exceed the limits indicated by zone 2,

Strona 4 - Use of this Guide

Quick Start GuideD103203X012DVC2000 Digital Valve ControllerApril 2014125. Tighten the fasteners and remove the alignment template. Continue on with

Strona 5 - Valve / Actuator Mounting

Quick Start GuideD103203X012DVC2000 Digital Valve ControllerApril 201413Air‐to‐Close GX Actuators6. Remove the cover of the digital valve controller.

Strona 6

Quick Start GuideD103203X012DVC2000 Digital Valve ControllerApril 201414Guidelines for Mounting on Quarter‐Turn (Rotary) ActuatorsThe DVC2000 digital

Strona 7

Quick Start GuideD103203X012DVC2000 Digital Valve ControllerApril 201415Electrical and Pneumatic ConnectionsThe electrical and pneumatic connections o

Strona 8

Quick Start GuideD103203X012DVC2000 Digital Valve ControllerApril 201416Wire the digital valve controller as follows:1. Remove the main instrument co

Strona 9

Quick Start GuideD103203X012DVC2000 Digital Valve ControllerApril 2014174. If a second switch is to be used, connect the control system input card po

Strona 10 - Mounting on GX Actuators

Quick Start GuideD103203X012DVC2000 Digital Valve ControllerApril 201418Basic Setup and CalibrationThe local operator interface is available on all DV

Strona 11 - Quick Start Guide

Quick Start GuideD103203X012DVC2000 Digital Valve ControllerApril 201419Basic Setup WARNINGChanges to the instrument setup may cause changes in the o

Strona 12

Quick Start GuideD103203X012DVC2000 Digital Valve ControllerApril 20142Local Interface Flow Chart TRAVEL = 66.8%14.6 MA 0.92 BARQUICK SETUPYBYYBBYBBY

Strona 13

Quick Start GuideD103203X012DVC2000 Digital Valve ControllerApril 201420Quick SetupWhen installing the DVC2000 digital valve controller on an actuator

Strona 14

Quick Start GuideD103203X012DVC2000 Digital Valve ControllerApril 201421Travel Calibration WARNINGDuring calibration the valve will move full stroke.

Strona 15 - Electrical Connections

Quick Start GuideD103203X012DVC2000 Digital Valve ControllerApril 201422Tuning WARNINGChanges to the tuning set may cause the valve/actuator assembly

Strona 16 - Limit Switches

Quick Start GuideD103203X012DVC2000 Digital Valve ControllerApril 201423Table 3. Gain Values for Preselected Turning SetsTuning Set Proportional Gain

Strona 17 - Communications Connections

Quick Start GuideD103203X012DVC2000 Digital Valve ControllerApril 201424The factory default characteristic is LINEAR. You can also use a QUICK OPEN, E

Strona 18 - Status Information

Quick Start GuideD103203X012DVC2000 Digital Valve ControllerApril 201425Figure 21. XMTR SwitchTRANSMITTER SWITCHFOR FAIL SIGNAL+ HIGH (SHOWN) OR-LOWW8

Strona 19 - Basic Setup

Quick Start GuideD103203X012DVC2000 Digital Valve ControllerApril 201426Figure 22. Position Transmitter CalibrationSAVE & EXIT?EXIT W/O SAVING?SAV

Strona 20 - Quick Setup

Quick Start GuideD103203X012DVC2000 Digital Valve ControllerApril 201427The UP (Y) and DOWN (B) arrow keys will allow you to change the setpoint and t

Strona 21 - Travel Calibration

Quick Start GuideD103203X012DVC2000 Digital Valve ControllerApril 201428Once switch circuit 1 is powered properly, question marks (???) will indicate

Strona 22 - WARNING

Quick Start GuideD103203X012DVC2000 Digital Valve ControllerApril 201429Specifications Available ConfigurationsJ Integral mounting to the GX actuato

Strona 23 - Detailed Setup

Quick Start GuideD103203X012DVC2000 Digital Valve ControllerApril 20143YYYYYYYYYYYYYVALVE MAY MOVEPRESS  FOR 3 SECSAVE AND EXIT?PRESS EXIT W/O SAVIN

Strona 24

Quick Start GuideD103203X012DVC2000 Digital Valve ControllerApril 201430Specifications (continued)Other Classifications/CertificationsGOST‐R—Russian G

Strona 25

Quick Start GuideD103203X012DVC2000 Digital Valve ControllerApril 201431Table 4. EMC Summary Results—ImmunityPort Phenomenon Basic Standard Test Level

Strona 26 - Local Control

Quick Start GuideD103203X012DVC2000 Digital Valve ControllerApril 201432Related DocumentsOther documents containing information related to the DVC2000

Strona 27

Quick Start GuideD103203X012DVC2000 Digital Valve ControllerApril 201433Hazardous Area Classifications and Special Instructions for “SafeUse” and Inst

Strona 28

Quick Start GuideD103203X012DVC2000 Digital Valve ControllerApril 201434Figure 25. CSA Installation DrawingGE12444‐C EQUIPMENT SHALL BE INSTALLED IN

Strona 29 - J Sliding‐stem applications

Quick Start GuideD103203X012DVC2000 Digital Valve ControllerApril 201435Figure 26. Typical FM NameplateFigure 27. FM Installation DrawingGE10683‐DHAZA

Strona 30 - Specifications (continued)

Quick Start GuideD103203X012DVC2000 Digital Valve ControllerApril 201436ATEXSpecial Conditions for Safe UseIntrinsically SafeThe equipment is an intri

Strona 31

Quick Start GuideD103203X012DVC2000 Digital Valve ControllerApril 201437Figure 29. ATEX Installation DrawingGE14685‐C INSTALLATION MUST BE IN ACCORDA

Strona 32 - Educational Services

Quick Start GuideD103203X012DVC2000 Digital Valve ControllerApril 201438IECExConditions of CertificationIntrinsically SafeThis equipment shall be conn

Strona 33

Quick Start GuideD103203X012DVC2000 Digital Valve ControllerApril 201439Figure 31. IECEx Installation DrawingGE14581‐C INSTALLATION MUST BE IN ACCORD

Strona 34

Quick Start GuideD103203X012DVC2000 Digital Valve ControllerApril 20144Use of this GuideThis guide describes how to install the digital valve controll

Strona 35

Quick Start GuideD103203X012DVC2000 Digital Valve ControllerApril 201440Emerson Process Management Marshalltown, Iowa 50158 USASorocaba, 18087 BrazilC

Strona 36

Quick Start GuideD103203X012DVC2000 Digital Valve ControllerApril 20145InstallationNoteThe DVC2000 is not designed to correct for significant stem rot

Strona 37

Quick Start GuideD103203X012DVC2000 Digital Valve ControllerApril 20146The DVC2000 housing is available in four different configurations, depending on

Strona 38

Quick Start GuideD103203X012DVC2000 Digital Valve ControllerApril 20147NoteAs a general rule, do not use less than 50% of the magnet array for full tr

Strona 39

Quick Start GuideD103203X012DVC2000 Digital Valve ControllerApril 20148Sliding-Stem (Linear) Actuators1. Isolate the control valve from the process l

Strona 40

Quick Start GuideD103203X012DVC2000 Digital Valve ControllerApril 201496. Tighten the fasteners and remove the alignment template.NoteUse a flat end