Emerson OpenComms-485 Dokumentacja

Przeglądaj online lub pobierz Dokumentacja dla Networking Emerson OpenComms-485. Emerson OpenComms-485 Specifications [en] Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 48
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
MONITORING
SITESCAN WEB
SOLUTIONS GUIDE
Przeglądanie stron 0
1 2 3 4 5 6 ... 47 48

Podsumowanie treści

Strona 1 - SITESCAN WEB

MONITORINGSITESCAN WEB SOLUTIONS GUIDE

Strona 2 -

Product Description42.2 Custom Software Development Determine the number of graphics necessary for the customer. By default, SiteScan Web includes a g

Strona 3 - TABLE OF CONTENTS

Product Description52.3 Gateway ModulesIn SiteScan Web, Liebert gateways route BACnet over IP traffic between Liebert gateways and the Web server. The

Strona 4

Product Description62.4 SiteLink ModulesA SiteLink module receives IGM protocol from Liebert environmental and power equipment and con-verts it to BAC

Strona 5

Product Description72.5 Site I/O ModulesA Site I/O module is used to interface to dry contacts or sensors, the types of connections required to monito

Strona 6

Product Description82.6 Stand-Alone Monitoring ModulesThe Liebert stand-alone monitoring modules include the RPMP, Universal Monitor and Liqui-tect Mo

Strona 7 - 1.0 SYSTEM OVERVIEW

Product Description92.7 Module Accessories2.7.1 GXEXP - Expander CableThe Site I/O Expander Cable is an 18-inch long or 24-inch long expander cable us

Strona 8

Product Description102.8 ARCnet Communication Enhancement DevicesIn SiteScan Web systems, ARCnet, or ARC156, is the standard for module-to-module comm

Strona 9 - 2.0 PRODUCT DESCRIPTION

Product Description112.9 Third-Party InterfacesThe SiteTPI-E is designed to communicate with third-party equipment that uses Modbus or BACnet. Use a S

Strona 10 - Product Description

Application and Configuration123.0 APPLICATION AND CONFIGURATION3.1 Single-Site - SiteScan Web System Not on Customer’s Ethernet3.1.1 Target Applicati

Strona 11 - 2.3 Gateway Modules

Application and Configuration133.2 Multiple Data Centers in the Same Building3.2.1 Target ApplicationIn a typical application, a customer wants to mon

Strona 13 - 2.5 Site I/O Modules

Application and Configuration143.3 Multiple Sites Using Customer’s Intranet3.3.1 Target ApplicationIn a typical application, a customer has multiple d

Strona 14 - 2.6.1 RPMP

Application and Configuration153.4 Hierarchical Servers - SiteScan Web with WebCTRL3.4.1 Target ApplicationIn a typical application, a customer has a

Strona 15 - 2.7 Module Accessories

Application and Configuration163.5 Redundant SiteScan Web Servers3.5.1 Target ApplicationIn a typical application, a customer wants to monitor two fac

Strona 16

Application and Configuration173.6 SiteScan Web and Rack Monitoring3.6.1 Target ApplicationIn a typical application, a customer has a data center that

Strona 17 - 2.9 Third-Party Interfaces

Upgrading SiteScan 2000 Systems to SiteScan Web184.0 UPGRADING SITESCAN 2000 SYSTEMS TO SITESCAN WEBA SiteScan Web upgrade allows an existing SS2000 o

Strona 18 - PPLICATION AND CONFIGURATION

Upgrading SiteScan 2000 Systems to SiteScan Web194.1 Upgrade OverviewSiteScan Web Upgrade comes with all the same basic functionality as SiteScan Web.

Strona 19 - 3.2.2 Description

Upgrading SiteScan 2000 Systems to SiteScan Web204.2 Upgrading SS2WA SiteScan Web upgrade of an existing SiteScan 2W system requires replacing each DC

Strona 20 - 3.3.3 Bill of Materials

Upgrading SiteScan 2000 Systems to SiteScan Web214.3 Upgrading SS2000W While Maintaining Existing WiringA SiteScan Web upgrade of an existing SiteScan

Strona 21 - 3.4.3 Bill of Materials

Upgrading SiteScan 2000 Systems to SiteScan Web224.4 Upgrading SS2000W to Full SiteScan WebA full SiteScan Web upgrade of an existing SiteScan 2000W s

Strona 22 - 3.5.3 Bill of Materials

Third-Party and Building Management Interfaces235.0 THIRD-PARTY AND BUILDING MANAGEMENT INTERFACESSiteScan Web monitoring products can provide multipl

Strona 23 - 3.6.3 Bill of Materials

iTABLE OF CONTENTS1.0 SYSTEM OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11.1

Strona 24

Third-Party and Building Management Interfaces245.2 BACnet/IP to BMS Without a SiteScan Web Front-End5.2.1 Target ApplicationA typical application mig

Strona 25 - 4.1 Upgrade Overview

Third-Party and Building Management Interfaces255.3 BMS Front-End Interfacing to Liebert Equipment by EIA-485 ModbusModbus is an industry standard mea

Strona 26 - 4.2 Upgrading SS2W

Third-Party and Building Management Interfaces265.3.2 Port A—RS-232 to RS-485 ModbusIf the third-party device communicates using RS-232 point-to-point

Strona 27 - 4.3.3 Bill of Materials

Third-Party and Building Management Interfaces275.3.4 Combining SSWEB and ModbusIt is possible to have a Modbus system communicating to a SiteScan Web

Strona 28 - 4.4.3 Bill of Materials

Third-Party and Building Management Interfaces285.4 SiteTPI-E with OpenComms NIC (or OpenComms 485)Customer has installed OpenComms NIC cards in Liebe

Strona 29 - 5.1.3 Bill of Materials

Third-Party and Building Management Interfaces295.5 Basic SiteTPI-E with Third-Party EquipmentCustomer wants to monitor third-party equipment with Sit

Strona 30 - 5.2.3 Bill of Materials

Third-Party and Building Management Interfaces305.6 SiteTPI-E and Third-Party Equipment with Different Modbus ProtocolCustomer wants to monitor third-

Strona 31 - Port A—RS-485 Modbus

ARCnet156316.0 ARCNET1566.1 ARCnet156 CMnet ComponentsThe SSWEB-Liebert gateways and control modules communicate using ARCnet156, a token-passing prot

Strona 32 - 5.3.3 Port B—RS-232 Modbus

ARCnet156326.3 TerminationsAt 156 Kbps, a signal reaching the end of an unterminated cable can echo, or reflect back, creating a distortion in the sig

Strona 33

ARCnet156336.5 Cable ShieldsConnect the shields as shown in Figure 23. The shields should be connected at each module’s shield connection terminal.Do

Strona 34 - 5.4.3 Bill of Materials

ii3.0 APPLICATION AND CONFIGURATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .123.1 Single-Site - SiteScan Web

Strona 35 - SiteLink-12

ARCnet156346.7 Upgrading to ARC156Before upgrading a legacy CMnet to ARC156, you must:• Ensure adequate wiring. See 6.4 - Wiring Recommendations for d

Strona 36 - 4 – Wire Modbus

Wiring Guidelines357.0 WIRING GUIDELINESTable 22 Standard SiteScan Web wiringApplication Max. Cable Length Cable RecommendationARC156 CMnet 2000 ft.

Strona 37 - 6.0 ARCNET156

Wiring Guidelines36NOTES

Strona 38 - 6.4 Wiring Recommendations

Terminology37APPENDIX A-TERMINOLOGYARCnetThe protocol used for communications between the Liebert gateway and the Liebert control modules. This is a t

Strona 39 - 6.6 Noise

Terminology38Liebert GatewayAlso referred to as a router, the Liebert gateway routes information between the Web server and the Liebert control module

Strona 40 - 6.7 Upgrading to ARC156

Terminology39RouterA device that forwards data packets from one local area network (LAN) or wide area network (WAN) to another. Based on routing table

Strona 43 - APPENDIX A-TERMINOLOGY

The Company Behind the ProductsWith over a million installations around the globe,Liebert is the world leader in computer protectionsystems. Since its

Strona 44 - Terminology

iii5.0 THIRD-PARTY AND BUILDING MANAGEMENT INTERFACES . . . . . . . . . . . . . . . . . . . . . . . . .235.1 SiteScan Web and BACnet/IP to BMS . . .

Strona 45

ivFIGURESFigure 1 Single-site - SiteScan Web system not on customer’s Ethernet . . . . . . . . . . . . . . . . . . . . . . . . . . 12Figure 2 Multi

Strona 46

System Overview11.0 SYSTEM OVERVIEWSiteScan Web uses a network of microprocessor-based control modules to monitor and control Liebert air, power, UPS

Strona 47

System Overview21.2 Typical SiteScan Web SystemA typical SiteScan Web system may include the components shown in the figure below.Site I/O 16/16Third-

Strona 48

Product Description32.0 PRODUCT DESCRIPTION2.1 Application SoftwareSiteScan Web is based on server/thin-client architecture, designed around the open

Komentarze do niniejszej Instrukcji

Brak uwag