2625 Volume Booster
D200071X012
Product Bulletin
62.3:2625
January 2015
2
Specifications
Supply Pressure Ranges
When used in conjunction with a positioner or other
pneumatic accessory, always pipe the positioner and
volume booster with one common supply through a
Fisher 67D, 67DR, or 95H regulator (see figure 2). A
high‐capacity filter, such as the Fisher 262K, should
be installed in the supply line to the regulator. Supply
pressure also must not exceed the maximum
pressure rating of the actuator. Constructions are
available in two maximum supply ranges.
When Normally Used With Diaphragm Actuators: Up
to 2.8 bar (40 psig)
When Normally Used With Piston Actuators: Up to
10.3 bar (150 psig)
Input Signal Pressure
Positioner output
Maximum Input Signal Pressure
10.3 bar (150 psig)
Fixed Input‐to‐Output Pressure Ratio
1 to 1
Nominal Deadband
Percent of Positioner Output Span
(1)
:
2.4 mm (0.094 inch) exhaust port: 2%
9.5 mm (0.375 inch) exhaust port: 3.5%
12.7 mm (0.5 inch) exhaust port: 5%
Construction Materials
Body: Aluminum
Seat Ring: Brass
Diaphragms
2625: Nitrile/nylon
2625NS: EPDM/meta‐aramid
Upper and Lower Valves:
2625: Nitrile‐CSM rubber/aluminum/stainless steel
2625NS: EPDM/aluminum/stainless steel
O‐Rings:
2625: Nitrile
2625NS: EPDM
Connectors for Diagnostic Testing:
J Stainless steel
or
J brass
Operative Temperature Limits
(2)
2625: -40 to 71_C (-40 to 160_F)
2625NS: -40 to 93_C (-40 to 200_F)
Connections
Input Signal: 1/4 NPT
Supply and Output: 3/4 NPT
Port Diameters
(3)
Supply Port: J9.5 mm (0.375 inch) or
J 12.7 mm (0.5 inch)
Exhaust Port:
J2.4 mm (0.094 inch),
J9.5 mm (0.375 inch) or J12.7 mm (0.5 inch)
Maximum Flow Coefficients
See table 1
Hazardous Area Classification
Complies with the requirements of ATEX Group II
Category 2 Gas and Dust
Safety Instrumented System Classification
SIL3 capable - certified by exida Consulting LLC
Approximate Weight
2.3 kg (5 lb)
NOTE: Specialized instrument terms are defined in ANSI/ISA Standard 51.1 - Process Instrument Terminology.
1. Zero to maximum supply.
2. The pressure/temperature limits in this document and any applicable code or standard should not be exceeded.
3. May be used in any combination.
Komentarze do niniejszej Instrukcji