Bulletin 71.2:92S
D100621X012
December 2011
www. sherregulators.com
Type 92S Pilot-Operated Steam Regulator
Introduction
The Type 92S steam regulator is piston actuated for
high cycle steam service which includes a Type 6492L,
6492H, or 6492HT pilot (see Figure 1). These pilots
have bellows sealed stems to eliminate stem guide
friction. The valve and pilot use lapped seating surfaces
that have been proven to minimize seat leakage.
Features
Good Shutoff for Low Downstream Build-up—
Type 92S main valve and Types 6492H, 6492L, and
6492HT pilots are machine-lapped seating surfaces
that have been time-proven to minimize seat leakage
when the downstream demand is zero and the
regulator is shutoff.
Resistance to Piping Stresses—Steel
constructions are available to help resist the piping
stresses commonly encountered in steam applications.
Ease of Installation—Compact construction
reduces installation space requirements. Supply of
pressure to the pilot is supplied from the inlet side
of the main valve through factory piped tubing;
with a standard pilot, this means no separate pilot
supply pressure is required.
Increased Sensitivity to Downstream Pressure
Changes—Friction-reducing bellows seal on
the pilot stem and large pilot diaphragm areas
yield good sensitivity.
Ease of Pilot Maintenance—Pilot valve plug and
seat can be removed for inspection of maintenance
without disassembling piping connections and
without removing the diaphragm. Pilot inlet screen
(Figure 2) is easily removed with the seating
parts for inspection and cleaning. Diaphragm can
be removed without disturbing the seating parts.
Noise Reduction Capability Without Decrease
in Capacity—A noise attenuation trim is
available for use with NPS 2 / DN 50 and larger
main valve sizes to provide an economical yet
full- ow means for the reduction of noise from high
velocity steam  ow. Further noise reduction of
the system can be achieved by the use of a heavier
piping schedule and/or thermal insulation of the
attached piping.
W4086_3
1 NPT STEEL
MAIN VALVE WITH TYPE 6492H OR 6492HT PILOT
W4088_1
NPS 3 / DN 80 FLANGED CAST IRON
MAIN VALVE WITH TYPE 6492L PILOT
Figure 1. Type 92S Pilot-Operated Steam Regulator
Przeglądanie stron 0
1 2 3 4 5 6 ... 15 16

Podsumowanie treści

Strona 1 - Bulletin 71.2:92S

Bulletin 71.2:92SD100621X012December 2011www. sherregulators.comType 92S Pilot-Operated Steam RegulatorIntroductionThe Type 92S steam regulator is pi

Strona 2

Bulletin 71.2:92S10A3330/ILOUTLET PRESSURE, psigFLOW kg/h OF SATURATED STEAMOUTLET PRESSURE, barFLOW, POUNDS/HOUR OF SATURATED STEAM1000 2000

Strona 3

Bulletin 71.2:92S11Table 5. Flow Capacities in Pounds per Hour / kg/h of Saturated Steam- continued -OUTLET PRESSURE SETTING(1) PILOT TYPE NUMBERINLE

Strona 4

Bulletin 71.2:92S12Table 5. Flow Capacities in Pounds per Hour / kg/h of Saturated Steam (continued)Table 6. Noise Level Data in Decibels with Sched

Strona 5

Bulletin 71.2:92S13Table 6. Noise Level Data in Decibels with Schedule 40 Downstream Piping and No Insulation(1)(continued)P1PERCENTAGE OF MAXIMUM RE

Strona 6

Bulletin 71.2:92S141/4 NPT CONTROL LINE CONNECTION ON BACKSIDEBETRIM REMOVAL CLEARANCEA/2A17A8559-AB1904RSNPS 1, 1-1/2, OR 2 / DN 25, 40, OR 50 MAIN V

Strona 7

Bulletin 71.2:92S15Body Size (Select One) NPS 1 / DN 25** NPS 1-1/2 / DN 40** NPS 2 / DN 50*** NPS 2-1/2 / DN 65* NPS 3 / DN 80** N

Strona 8

Bulletin 71.2:92S©Emerson Process Management Regulator Technologies, Inc., 1984, 2011; All Rights ReservedThe Emerson logo is a trademark and service

Strona 9

Bulletin 71.2:92S2SpecicationsMain Valve Body Sizes and End Connection StylesBODY SIZESEND CONNECTION STYLES AND RATINGSCast Iron BodySteel orStainle

Strona 10

Bulletin 71.2:92S3Specications (continued)Maximum Temperature Capabilities(1) Cast Iron Main Valve and Pilot: 406°F / 208°C Steel Main Valve and

Strona 11

Bulletin 71.2:92S4 • Lapped Seats for Tight Shutoff—The valve and pilot use lapped seating surfaces that have been proven to minimize se

Strona 12

Bulletin 71.2:92S5NPS 1, 1-1/2, OR 2 / DN 25, 40, OR 50 MAIN VALVE BODY AND TYPE 6492H OR 6492HT PILOTFigure 2. Type 92S Pressure Reducing Regulator

Strona 13

Bulletin 71.2:92S6TE0402Figure 3. NPS 1, 1-1/2, and 2 / DN 25, 40, and 50 Type 92S Pilot-Operated Pressure Reducing Regulator with Safety Override Pi

Strona 14

Bulletin 71.2:92S7TYPESPRING RANGESPRING COLOR PART NUMBERMINIMUM PRESSURE AT WHICH MONITORING PILOT CAN BE SETpsig bar6492HM10 to 30 0.69 to 2.1 Yel

Strona 15

Bulletin 71.2:92S8Type 92S Pilot-Operated Pressure Reducing Regulator with Safety Override PilotA Type 6492HM or 6492HTM safety override pilot is avai

Strona 16

Bulletin 71.2:92S9Figure 6. NPS 2-1/2, 3, and 4 / DN 65, 80, and 100 Piping SchematicsTYPE 92S MAIN VALVETYPE 6492H PILOTBOTTOM VIEWNoise level value