Emerson ACE95Sr Instrukcja Obsługi Strona 2

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 16
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 1



Angled Body*: 3/4 NPT
1 NPT
NPS 1 (DN 25), CL150RF
NPS 1 (DN 25), CL300RF
NPS 1 (DN 25), PN16/25/40RF
NPS 1 (DN 25) Sanitary Flange
In-Line Body: 3/4 NPT
1 NPT
NPS 1 (DN 25), CL150RF
NPS 1 (DN 25), CL300RF
NPS 1 (DN 25), PN16/25/40RF
NPS 1 x 2 (DN 25 x 50), CL150RF
NPS 1 x 2 (DN 25 x 50), PN16/25/40RF
NPS 1 (DN 25), Sanitary Flange

Angled Body*: 2 NPT
NPS 2 (DN 50), CL150RF
NPS 2 (DN 50), CL300RF

200 psig (13,8 bar)

20 psig (1,4 bar)

1.5 psig (0,10 bar)

-5.0-inches w.c. to 1.5 psig (-12 mbar to 0,10 bar)
see Table 1

External

Typically within 0.5-inches w.c. (1 mbar) when
owing 5 to 70 percent of advertised capacities.

Linear

: :
C
v
1 use C
v
1.1 C
v
20 use C
v
22
C
v
2 use C
v
2.2 C
v
45 use C
v
50
C
v
4 use C
v
4.4 C
v
60 use C
v
66
C
v
7.5 use C
v
9.25
C
v
10 use C
v
11


–20° to 180°F (–29° to 82°C)

0° to 212°F (–18° to 100°C)

–20° to 212°F (–29° to 100°C)

–20° to 212°F (–29° to 100°C)


Type ACE95: 40 pounds (18 kg)
Type ACE95Sr: 60 pounds (27 kg)
Table 1. Control Pressure Ranges
 




-5 to -0.5-inches w.c. (-12 to -1 mbar) Stainless Steel
2.75
0.88
(69,9)
(22,4)
(1)
0.080
0.085
(2,03)
(2,16)
(1)
-1 to 1-inches w.c. (-2 to 2 mbar) Stainless Steel
2.75
1.60
(69,9)
(40,6)
(1)
0.080
0.065
(2,03)
(1,65)
(1)
0.5 to 5-inches w.c.
4 to 10-inches w.c.
8 to 15-inches w.c.
0.5 to 1.5 psig
(1 to 12 mbar)
(10 to 25 mbar)
(20 to 37 mbar)
(0,03 to 0,10 bar)
Stainless Steel
Stainless Steel
Stainless Steel
Stainless Steel
2.75
2.00
2.00
2.75
(69,9)
(50,8)
(50,8)
(69,9)
0.080
0.112
0.125
0.225
(2,03)
(2,84)
(3,18)
(5,72)
1. The second spring is located under the diaphragm assembly.

ACE95 Series tank blanketing valves are pilot
operated, activated by the diaphragm, and control the
vapor space pressure over a stored liquid. The unit
is controlled by a very large diaphragm actuator. The
oversized actuator offers high sensitivity to changes
in tank pressure. When a storage tank cools and
tank vapors condense, ACE95 Series valves replace
the condensing vapors with an inert gas to prevent
internal tank pressure from decreasing. Positive tank
pressure prevents outside air from contaminating the
product and reduces the possibility of atmospheric
pressure collapsing the tank. As demand is satised,
the valve closes.
*Various Single Array Manifold (SAM) tank connections are also available. Contact your local Sales Ofce for more information.