Emerson T205 Instrukcja Obsługi

Przeglądaj online lub pobierz Instrukcja Obsługi dla Nie Emerson T205. Emerson T205 Instruction Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 12
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
T205 Series
D103748X012
Instruction Manual
April 2014
www.fisherregulators.com
T205 Series Tank Blanketing Regulators
Table of Contents
Introduction ............................................................................ 1
Specifications ........................................................................2
Principle of Operation ............................................................3
Installation .............................................................................3
Overpressure Protection........................................................5
Startup, Adjustment and Shutdown .......................................5
Adjustment.............................................................................6
Shutdown...............................................................................6
Maintenance ..........................................................................6
Parts Ordering .......................................................................9
Parts List................................................................................9
WARNING
!
Failure to follow these instructions or to
properly install and maintain this equipment
could result in an explosion,  re and/or
chemical contamination causing property
damage and personal injury or death.
Fisher
®
regulators must be installed,
operated and maintained in accordance
with federal, state and local codes, rules
and regulations and Emerson Process
Management Regulator Technologies Inc.
(Regulator Technologies) instructions.
If the regulator discharges process  uid or
a leak develops in the system, service to
the unit may be required. Failure to correct
trouble could result in a hazardous condition.
Call a quali ed service person to service the
unit. Installation, operation and maintenance
procedures performed by unquali ed
person may result in improper adjustment
and unsafe operation. Either condition may
result in equipment damage or personal
injury. Only a quali ed person must install or
service the T205 Series regulator.
Figure 1. Type T205 Tank Blanketing Regulator
Introduction
Scope of the Manual
This Instruction Manual provides instruction for installation,
startup, maintenance and parts ordering information for the
T205 Series tank blanketing regulators.
Product Description
T205 Series tank blanketing regulator is a direct-operated
and spring-loaded regulator. The regulator prevents a stored
liquid from vaporizing into the atmosphere, reduces liquid
combustibility and prevents oxidation or contamination of
the product by reducing its exposure to air. T205 Series
maintains a slightly positive pressure and thereby
reduces the possibility of tank wall collapse during pump
out operation.
T205 Series is available in two con gurations: Type T205
for internal pressure registration requiring no downstream
control line and Type T205M which has a blocked throat
and a downstream control line connection for external
pressure registration.
Przeglądanie stron 0
1 2 3 4 5 6 ... 11 12

Podsumowanie treści

Strona 1 - T205 Series

T205 SeriesD103748X012Instruction ManualApril 2014www.fisherregulators.comT205 Series Tank Blanketing RegulatorsTable of ContentsIntroduction ...

Strona 2

T205 Series10Figure 7. Type T205 Regulator Assembly with Internal Registration APPLY LUBRICANT(1): L1 = SILICONE GREASE L2 = ANTI-SEIZE COMPOUND1.

Strona 3

T205 Series11Figure 8. Type T205M Regulator Assembly with External RegistrationERSA02736 APPLY LUBRICANT(1): L1 = SILICONE GREASE L2 = ANTI-SEIZE C

Strona 4

T205 Series©Emerson Process Management Regulator Technologies, Inc., 2013, 2014; All Rights ReservedThe Emerson logo is a trademark and service mark o

Strona 5

T205 Series2SpecicationsThe Specications section on this page provides the ratings and other specications for the T205 Series. Factory specication

Strona 6

T205 Series3Principle of OperationT205 Series tank blanketing regulator controls the vapor space pressure over a stored liquid. When liquid is pumped

Strona 7

T205 Series4Figure 3. Type T205M with External Registration Operational SchematicsFigure 2. Type T205 with Internal Registration Operational Schematic

Strona 8

T205 Series55. Type T205M requires a downstream control line. Be sure to install the control line before putting the regulator into operation. Make t

Strona 9

T205 Series62. Slowly open the supply line shutoff valve (to the blanketing valve) and leave it fully open.3. Monitor the tank vapor space pressure.

Strona 10

T205 Series7manufactured by Regulator Technologies should be used for repairing Fisher® regulators. Restart gas utilization equipment according to nor

Strona 11

T205 Series8 For internal at circular adjusting screw: a. Remove the adjusting screw (key 35). b. Take out the control spring and replace with

Strona 12

T205 Series9To Convert ConstructionsFrom Type T205 to Type T205MA control line is needed. New parts required: keys 30, 31 and 17.1. Remove pipe plug

Komentarze do niniejszej Instrukcji

Brak uwag