D103748X014
Installation Guide
English – August 2013
T205 Series
www.fisherregulators.com
Introduction
This installation guide provides instructions for installation,
startup, and adjustment. To receive a copy of the instruction
manual, contact your local Sales Ofce or view a copy at
www.fisherregulators.com. For further information refer to:
T205 Series Tank Blanketing Regulators Instruction
Manual, D103748X012.
P.E.D. Categories
This product may be used as a safety accessory with
pressure equipment in the following Pressure Equipment
Directive 97/23/EC categories.
It may also be used
outside of the Pressure Equipment Directive using sound
engineering practice (SEP) per table below.
PRODUCT SIZE CATEGORIES FLUID TYPE
DN 20 and 25 / 3/4 and 1 inch SEP 1


Type T205: Tank blanketing regulator with outlet
pressure range of 2.5 mbar to 0.48 bar / 1 inch w.c.
to 7 psig in seven different spring ranges and has
internal pressure registration requiring no downstream
control line.
Type T205M: Similar to Type T205 but has a blocked
throat and a downstream control line connection for
external pressure registration.
Body Sizes and End Connection Styles
See Table 1
Maximum Allowable and Operating Inlet Pressure
(1)
See Tables 1 and 4
Maximum Outlet (Casing) Pressure
(1)
See Table 1
Maximum Emergency Outlet Pressure to Avoid Internal
Parts Damage
(1)
With Nitrile (NBR) or Fluorocarbon (FKM)
diaphragm: 2.4 bar / 35 psig
With Fluorinated Ethylene Propylene (FEP)
diaphragm: 1.4 bar / 20 psig
Outlet (Control) Pressure Ranges
(1)
See Table 3

Class VI (Soft Seat)
Pressure Registration
Type T205: Internal
Type T205M: External
Material Temperature Capabilities
(1)(2)
Nitrile (NBR): -29 to 82°C / -20 to 180°F
Fluorinated Ethylene Propylene (FEP):
-29 to 82°C / -20 to 180°F
Fluorocarbon (FKM): 4 to 149°C / 40 to 300°F
Ethylene Propylene Diene (EPDM):
-29 to 107°C / -20 to 225°F

-18 to 149°C / 0 to 300°F
1. The pressure/temperature limits in this Installation Guide and any applicable standard or code limitation should not be exceeded.
2. See Table 2 for operating temperature ranges for available trim combinations.
3. For proper operation to achieve the published capacities at low setpoint, the spring case barrel should be installed pointed down as shown in Figure 1.
Installation
!
WARNING

service a regulator. Regulators should
be installed, operated, and maintained
in accordance with international and
applicable codes and regulations,
and Emerson Process Management
Regulator Technologies, Inc. (Regulator
Technologies) instructions.

develops in the system, it indicates that

regulator out of service immediately may
create a hazardous condition.
Personal injury, equipment damage, or

pressure containing parts may result if this
regulator is overpressured or is installed
where service conditions could exceed the

or where conditions exceed any ratings of
the adjacent piping or piping connections.
To avoid such injury or damage, provide

devices (as required by the appropriate
code, regulation, or standard) to prevent
service conditions from exceeding limits.
Additionally, physical damage to the
regulator could result in personal injury

To avoid such injury and damage, install
the regulator in a safe location.
Clean out all pipelines before installation of the regulator
and check to be sure the regulator has not been damaged
or has collected foreign material during shipping. For
NPT bodies, apply pipe compound to the external pipe
threads. For anged bodies, use suitable line gaskets and
approved piping and bolting practices. Install the regulator
in any position desired
(3)
, unless otherwise specied, but
be sure ow through the body is in the direction indicated
by the arrow on the body.
Note
It is important that the regulator be
installed so that the vent hole in the
spring case is unobstructed at all times.
For outdoor installations, the regulator
should be located away from vehicular

and other foreign materials cannot enter
the spring case through the vent. Avoid
placing the regulator beneath eaves or
downspouts, and be sure it is above the
probable snow level.
Przeglądanie stron 0
1 2 3 4

Podsumowanie treści

Strona 1 - T205 Series

D103748X014Installation GuideEnglish – August 2013T205 Serieswww.fisherregulators.comIntroductionThis installation guide provides instructions for ins

Strona 2

2T205 SeriesOverpressure ProtectionT205 Series regulators have an outlet pressure rating lower than the inlet pressure rating. The recommended pressu

Strona 3

3T205 Series9750366383514181532510745816171149171312L2L1L1L21074581617123011491513L1L1L197503663835141831345L1 L2L2EXTERNAL SQUARE HEAD ADJUSTING SCRE

Strona 4

T205 Series©Emerson Process Management Regulator Technologies, Inc., 2013; All Rights ReservedThe Emerson logo is a trademark and service mark of Emer

Komentarze do niniejszej Instrukcji

Brak uwag