Emerson DLC3020f Przewodnik Szybki Start

Przeglądaj online lub pobierz Przewodnik Szybki Start dla Nie Emerson DLC3020f. Emerson DLC3020f Quick Start Guide Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 48
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
www.Fisher.com
Fisher
r
FIELDVUE
DLC3020f Digital Level
Controller for F
OUNDATION
fieldbus
Contents
Installation 3.....................
Mounting 10......................
Electrical Connections 14...........
Configuration 18..................
Calibration 33.....................
Nameplates and Schematics 37......
Specifications 41..................
Note
This quick start guide provides installation and initial setup and calibration information for the DLC3020f digital level controller
using AMS Suite: Intelligent Device Manager.
Quick Start Guide
D103470X012
DLC3020f Digital Level Controller
July 2012
This quick start guide applies to:
3020
1
1.0
1.0
0x03
Device Type
Device Revision
Hardware Revision
Firmware Revision
DD Revision
Przeglądanie stron 0
1 2 3 4 5 6 ... 47 48

Podsumowanie treści

Strona 1 - fieldbus

www.Fisher.comFisherr FIELDVUE™ DLC3020f Digital LevelController for FOUNDATION™ fieldbusContentsInstallation 3...Mounting 10...

Strona 2

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201210Mounting WARNINGTo avoid personal injury or property damage, always wear prot

Strona 3 - Installation

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201211The DLC3020f digital level controller is typically shipped attached to the sen

Strona 4 - Lever Lock

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 20121282463715SENSORCAGEDCAGELESSRIGHT‐OF‐DISPLACERLEFT‐OF‐DISPLACER1 NOT AVAILA

Strona 5

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201213HEAT INSULATORREQUIRED700 20 40 60 80 100 120 140 160010 20-20 -1030 40 50 604

Strona 6

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 2012146. Carefully slide the digital level controller with the attached insulator o

Strona 7

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 2012151. Remove the terminal box cover (key 6) from the terminal box (key 5).2. Br

Strona 8

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201216Communication Connections WARNINGPersonal injury or property damage caused by

Strona 9

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201217nConfiguration and Calibration Check ListConfiguration and Calibration complet

Strona 10 - Mounting

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201218ConfigurationNoteThis quick start guide documents procedures in AMS Device Man

Strona 11 - DLC3020f Orientation

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201219GUIDED SETUPINSTRUMENT SETUPCONFIGUREFigure 10. Guided SetupManual SetupAMS De

Strona 12

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 20122nInstallation Check ListInstrument correctly configured and mounted on the sens

Strona 13 - DIGITAL LEVEL CONTROLLER

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201220CONFIGUREMANUAL SETUPDEVICE TABSELECT UNIT SYSTEMSENSOR PARAMETERSVARIABLECONF

Strona 14 - Electrical Connections

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201221Sensor UnitsSelect the appropriate sensor units for your application.NoteDefau

Strona 15 - WARNING

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201222NoteTable 5 provides the driver rod length of 249 sensors with vertical displa

Strona 16 - Communication Connections

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201223HORIZONTAL CLOF TORQUE TUBEVERTICAL CL OF DISPLACERDISPLACER ROD LENGTHVESSELF

Strona 17 - July 2012

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201224Process FluidSelect the Process Fluid tab (figure 14) to access Process Fluid,

Strona 18 - Configuration

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201225Temperature CompensationIf Temperature Compensation is selected, provide the f

Strona 19 - Manual Setup

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201226Decimal PlacesEnter the number of desired decimal places for the device displa

Strona 20 - Sensor Hardware Information

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201227Primary ValuePV in engineering unitsPrimary Value PercentPV in %DI1 Trip Point

Strona 21 - Sensor Parameters

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201228MANUAL SETUPOPTIONS TABMODEWRITE ALARMCONFIGURERESOURCE BLOCKTRANSDUCER BLOCKA

Strona 22 - Table 5. Driver Rod Length

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201229Confirm TimeConfirm Time determines the time in 1/32 of a millisecond, the ins

Strona 23 - Torque Tube

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 20123InstallationDo not install, operate, or maintain a DLC3020f digital level contr

Strona 24 - Process Fluid

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201230Features SelectedNoteTypically this parameter does not need to be changed. The

Strona 25 - Instrument Display

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201231ALERT SETUPOPERATIONALALERT SETUP TABCONFIGUREELECTRONICSRATE LIMITSCROLL DOWN

Strona 26 - Snap Acting Control

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201232Maintenance— indicates a problem with the DLC3020f that, if ignored, could eve

Strona 27 - Write Alarm

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201233D Hall Sensor— when selected indicates if the Hall Sensor readings are out of

Strona 28 - Write Lock

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201234Calibrate InstrumentChoose Full Calibration (Bench) or Full Calibration (Field

Strona 29 - Function Block Available

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201235EXPERT USERCALIBRATIONS TABFULL CALIBRATIONTRIM CURRENT CALIBRATIONCONFIGURECA

Strona 30 - Alert Setup

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201236When complete, the torque rate or gain will be correct at the calibration temp

Strona 31 - PlantWeb Alerts

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201237Schematics and NameplatesThis section includes loop schematics required for wi

Strona 32 - Sensor Board

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201238 THE ENTITY CONCEPT ALLOWS INTERCONNECTION OF INTRINSICALLY SAFE APPARATUS TO

Strona 33 - Calibrate

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201239REFER TO FIGURE 25 FOR NOTESFigure 24. FM Schematic (Refer to figure 25 for No

Strona 34 - Expert User Calibrations

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 20124Protecting the Coupling and FlexuresCAUTIONDamage to flexures and other parts c

Strona 35 - Calibration Descriptions

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201240Figure 25. FM Schematics (Notes) THE ENTITY CONCEPT ALLOWS INTERCONNECTION OF

Strona 36 - Trim Current Calibration

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201241Instrument DescriptionThe FIELDVUE DLC3020f digital level controller (figure 2

Strona 37 - Schematics and Nameplates

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201242Related DocumentsOther documents containing information related to the DLC3020

Strona 38

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201243Table 6. SpecificationsAvailable ConfigurationsMounts on 249 caged and cageles

Strona 39

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201244Table 6. Specifications (continued)Alerts and DiagnosticsElectronic Alerts adv

Strona 40

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201245Table 7. FIELDVUE DLC3020f EMC Summary Results—ImmunityPort Phenomenon Basic S

Strona 41 - Specifications

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201246Table 10. Displacer and Torque Tube MaterialsPart Standard Material Other Mate

Strona 42 - Educational Services

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201247Table 12. Cageless Displacer Sensors(1)Mounting SensorStandard Head(2),Wafer B

Strona 43 - -continued

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201248Emerson Process Management Marshalltown, Iowa 50158 USASorocaba, 18087 BrazilC

Strona 44

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 201252. If the displacer cannot be blocked because of cage configuration or other c

Strona 45 - JReflex gauges for

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 20126Hazardous Area Classifications and Special Instructions for “Safe Use” andInsta

Strona 46

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 20127FMIntrinsically Safe, Explosion‐proof, Non-Incendive, Dust Ignition‐proofNo spe

Strona 47

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 20128ATEXSpecial Conditions for Safe UseIntrinsically Safe & DustThis apparatus

Strona 48

Quick Start GuideD103470X012DLC3020f Digital Level ControllerJuly 20129IECExConditions of CertificationIntrinsically Safe & DustThis apparatus sha

Komentarze do niniejszej Instrukcji