AE4-1287 R8
Copeland Discus
Compressors with
Demand Cooling
System
AE4-1287 R8 March 2015
TABLE OF CONTENTS
Section Page Section Page
Safety
Safety Instructions ...................................................2
Safety Icon Explanation ...........................................2
Instructions Pertaining to Risk of Electrical
Shock, Fire, or Injury to Persons ...........................3
Safety Statements ...................................................3
Introduction ...............................................................4
Updated Discharge Temperature Guidelines ...........4
Operating Range .....................................................4
Demand Cooling System .........................................4
Demand Cooling System Design .............................5
Demand Cooling Compressors ...............................5
Condenser Sizing ....................................................5
Demand Cooling System Components ...................5
Demand Cooling with CoreSense
Protection ........6
System Information ..................................................6
Demand Cooling with Discus
Compressor
Unloading ..............................................................6
4D and 6D Unloading with Demand Cooling ...........7
3D Copeland Discus Digital
compressors with
Demand Cooling ...................................................7
Performance Adjustment Factors ............................7
Demand Cooling Speci cations ...............................7
Figures and Tables
Demand Cooling System .........................................7
Low Temperature Operating Envelopes With and
Without Demand Cooling....................................8
CoreSense™ Discharge Temperature Protection....8
Standard Location of CoreSense
Temperature Probe ............................................9
Low Temperature Operating Envelope for R-22 at
65°F Return Gas (with Head Fan) ...................9
Demand Cooling System Diagram ........................10
Demand Cooling Wiring Schematics ................11-13
Demand Cooling Operating Setpoints and
Control Actions ....................................................14
Demand Cooling Kit Part Numbers .......................14
Appendix - Demand Cooling Diagnostics ...... 15-18
Przeglądanie stron 0
1 2 3 4 5 6 ... 17 18

Podsumowanie treści

Strona 1 - TABLE OF CONTENTS

1© 2015 Emerson Climate Technologies, Inc.AE4-1287 R8Copeland Discus™ Compressors with Demand Cooling™ SystemAE4-1287 R8 March 2015TABLE OF CONTENTSSe

Strona 2

10© 2015 Emerson Climate Technologies, Inc.AE4-1287 R8DEMAND-COOLINGCONTROL MODULETO CONTROLCIRCUITREFRIGERANT INJECTION LINEMANUAL SHUTOFFVALVEINJECT

Strona 3

11© 2015 Emerson Climate Technologies, Inc.AE4-1287 R8CCL1L2L3L1L2LMLMAASCS2402NOTE: Compressors withinternal overload protectionMUST have some means,

Strona 4

12© 2015 Emerson Climate Technologies, Inc.AE4-1287 R8CCL1L2L3L1L2LMLMAAS2402NOTE: The control circuitmust be arranged so that theDemand Cooling Modul

Strona 5

13© 2015 Emerson Climate Technologies, Inc.AE4-1287 R8ControlCCL1L2L2L1120v240vM2LAInjectionSolenoidTemp.SensorInjector ControlSwitchLMASDemandCooling

Strona 6

14© 2015 Emerson Climate Technologies, Inc.AE4-1287 R8The contents of this publication are presented for informational purposes only and are not to be

Strona 7

15© 2015 Emerson Climate Technologies, Inc.AE4-1287 R8 Copeland® Demand Cooling® Diagnostics Demand Cooling Operating CharacteristicsThe Copeland Dema

Strona 8 - With Demand Cooling

16© 2015 Emerson Climate Technologies, Inc.AE4-1287 R8Bench Check of the Module and Injection ValveRequired equipment:• A controlled voltage source

Strona 9 - Required*

17© 2015 Emerson Climate Technologies, Inc.AE4-1287 R8is closed. If correct control voltage is not present, replace the module.3. If correct control

Strona 10 - AE4-1287 R8

18© 2015 Emerson Climate Technologies, Inc.AE4-1287 R8Form No. 92-91 R2 (4/09)be occasional Demand Cooling trips. If lowering system temperatures corr

Strona 11

2© 2015 Emerson Climate Technologies, Inc.AE4-1287 R8Safety InstructionsCopeland Discus™ compressors are manufactured according to the latest U.S. and

Strona 12

3© 2015 Emerson Climate Technologies, Inc.AE4-1287 R8ELECTRICAL SHOCK HAZARD• Disconnect and lock out power before servicing. • Discharge all capaci

Strona 13 - Figure 8E

4© 2015 Emerson Climate Technologies, Inc.AE4-1287 R8IntroductionEnergy effi ciency regulations drive continuous change in the availability of refriger

Strona 14

5© 2015 Emerson Climate Technologies, Inc.AE4-1287 R8Performance data for Demand Cooling compressors includes the effects of injection when it is requ

Strona 15 - Appendix

6© 2015 Emerson Climate Technologies, Inc.AE4-1287 R8C. The alarm signal for local or remote control. The alarm relay is energized, after a one minute

Strona 16

7© 2015 Emerson Climate Technologies, Inc.AE4-1287 R8Figure 1 – Demand Cooling Systemnomenclature beginning with -ADx (e.g. 4DKNF63KL-TSK-AD0) Demand

Strona 17

8© 2015 Emerson Climate Technologies, Inc.AE4-1287 R8Injection lines represent maximum operation point within discharge temperature limits of the comp

Strona 18 - Form No. 92-91 R2 (4/09)

9© 2015 Emerson Climate Technologies, Inc.AE4-1287 R8Figure 5 – Standard Location of CoreSense Temperature Probe (for compressors without CoreSense Di

Komentarze do niniejszej Instrukcji

Brak uwag