Type HSR
5
Figure 4. 7-inch w.c. / 17 mbar Setpoint Relief Curves (with lever disconnected, no vent piping and 3/4 or 1-inch / 19 or 25 mm vent)
Figure 5. 2 psig / 0.14 bar Setpoint Relief Curves (with lever disconnected, no vent piping and 3/4 or 1-inch / 19 or 25 mm vent)
OUTLET PRESSURE, psig / bar
INLET PRESSURE, psig / bar
10 /
0.69
1/2-INCH / 13 mm ORIFICE
3/8-INCH / 9.5 mm ORIFICE
1/4-INCH / 6.4 mm ORIFICE
3/16-INCH / 4.8 mm ORIFICE
1/8-INCH / 3.2 mm ORIFICE
9 /
0.62
8 /
0.55
7 /
0.48
6 /
0.41
5 /
0.35
4 /
0.28
3 /
0.21
2 /
0.14
1 /
0.07
0
0
20 /
1.4
40 /
2.8
60 /
4.1
80 /
5.5
100 /
6.9
120 /
8.3
140 /
9.7
10
0.69
INLET PRESSURE, psig / bar
OUTLET PRESSURE, psig / bar
1/2-INCH / 13 mm ORIFICE
3/8-INCH / 9.5 mm ORIFICE
1/4-INCH / 6.4 mm ORIFICE
3/16-INCH / 4.8 mm ORIFICE
1/8-INCH / 3.2 mm ORIFICE
9
0.62
8
0.55
7
0.48
6
0.41
5
0.35
4
0.28
3
0.21
2
0.14
1
0.07
0
0 20 /
1.4
40 /
2.8
60 /
4.1
80 /
5.5
100 /
6.9
120 /
8.3
140 /
9.7