Type Y692
D102031X012
Instruction Manual
Form 5347
August 2009
www.emersonprocess.com/regulators
Type Y692 Low-Pressure Gas Blanketing Regulator
Figure 1. Type Y692 Low-Pressure Gas Blanketing Regulators
W5930
!
WARNING
Failure to follow these instructions or
to properly install and maintain this
equipment could result in an explosion,
re and/or chemical contamination
causing property damage and personal
injury or death.
Fisher
®
regulators must be installed,
operated, and maintained in accordance
with federal, state, and local codes,
rules and regulations, and Emerson
Process Management Regulator
Technologies Inc. instructions.
If the regulator vents gas or a leak
develops in the system, service to the unit
may be required. Failure to correct trouble
could result in a hazardous condition.
Installation, operation, and maintenance
procedures performed by unqualied
personnel may result in improper
adjustment and unsafe operation. Either
condition may result in equipment
damage or personal injury. Use qualied
personnel when installing, operating,
and maintaining the Type Y692 Low-
Pressure Gas Blanketing Regulator.
Introduction
Scope of the Manual
This instruction manual provides installation, startup,
maintenance, and parts ordering information for the
Type Y692 Low-Pressure Gas Blanketing Regulator.
Product Description
The Accu-Pressure™ Type Y692 Gas Blanketing
Regulator (Figure 1) is a pressure reducing direct-
operated regulator with internal registration or external
pressure registration. It is used for accurate pressure
control on very low-pressure blanketing systems.
Blanketing with low-pressure gas helps prevent
corrosion, helps control emissions from the blanketed
product and helps protect against any contamination to
the blanketed product by atmospheric conditions.
The regulator will maintain a positive vessel
pressure reducing the possibility of vessel wall
collapse. The Type Y692 is available in NPS 1-1/2
and 2 (DN 40 and 50) body sizes.
Type Y692 with external pressure registration
regulators have a stem seal with O-rings and a
1/2 NPT control line connection in the diaphragm
case. The control line can be used to more accurately
control the pressure in the tank if the regulator is
mounted an extended distance from the control point.
The stem seal separates the body outlet pressure from
the diaphragm case.
Specications
The Specications section lists specications for
Type Y692 Gas Blanketing Regulator. Specications
for a given regulator as it originally comes from the
factory are stamped on the spring case nameplate.
Przeglądanie stron 0
1 2 3 4 5 6 ... 11 12

Podsumowanie treści

Strona 1 - Type Y692

Type Y692D102031X012Instruction ManualForm 5347August 2009www.emersonprocess.com/regulatorsType Y692 Low-Pressure Gas Blanketing RegulatorFigure 1. T

Strona 2

Type Y69210Figure 6. Type Y692 Regulator AssemblyINTERNAL REGISTRATIONAPPLY LUB /SEAL/ADH43B0674-B21226789201311191716281425274654443235130237447TYPE

Strona 3

Type Y69211APPLY LUB /SEAL/ADH4343B0674-CEXTERNAL REGISTRATIONFigure 6. Type Y692 Regulator Assembly (continued)2122678920131119171628142527465432351

Strona 4

Type Y692The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their prospective owners. Fisher

Strona 5

Type Y6922Specications 1. The pressure/temperature limits in this Instruction Manual and any applicable standard limitation should not be exceede

Strona 6

Type Y6923Principle of OperationThe Type Y692 Gas Blanketing Regulator reduces a high-pressure gas to maintain a positive low-pressure of blanket gas

Strona 7

Type Y6924Installation!WARNINGPersonal injury, equipment damage, or leakage due to escaping accumulated gas or bursting of pressure-containing parts m

Strona 8

Type Y6925by bursting of pressure containing parts or explosion of accumulated gas, never adjust the control spring to produce a control pressure high

Strona 9

Type Y6926into the pitot tube hole and secure by aring the end. Rotate the pitot tube so that it points into the outlet of the body (key 28) after t

Strona 10

Type Y6927the pusher post (key 8) and that the holes in the diaphragm align with the holes in the lower casing. 13. Install the spring case (key 23)

Strona 11

Type Y6928Key Description Part Number 22 Hex Nut (12 required) Zinc-plated steel 1A309324122 Stainless steel 1A309338992 23 Spring Cas

Strona 12

Type Y6929Figure 4. Type Y692 with a Light Control Spring AssemblyFigure 5. Type Y692 with a Heavy Control Spring Assembly34B4869-A34B4832-BTable 4.