Podsumowanie treści

Strona 1 - Transmitters

Instruction ManualP/N 20001909, Rev. DAAugust 2009ProLink® II Software for Micro Motion® TransmittersInstallation and Use Manual

Strona 2 - The Micro

4 ProLink® II Software for Micro Motion® TransmittersBefore You BeginFigure 1-1 Transmitter model numbers and codesR F T 9 7 3 9 x x x x x x xMounting

Strona 3 - Contents

Installation and Use Manual 5Before You BeginProLink II Setup Transmitter StartupUsing ProLink IIBefore You BeginFigure 1-1 Transmitter model numbers

Strona 4

6 ProLink® II Software for Micro Motion® Transmitters

Strona 5

Installation and Use Manual 7ProLink II Setup Transmitter StartupUsing ProLink IIBefore You BeginChapter 2Installation and Setup2.1 OverviewThis chapt

Strona 6

8 ProLink® II Software for Micro Motion® TransmittersInstallation and Setup(2) If the user who installs ProLink II does not have Administrator rights,

Strona 7 - Chapter 1

Installation and Use Manual 9Installation and SetupProLink II Setup Transmitter StartupUsing ProLink IIBefore You BeginWARNINGOn Model 3350/3700 trans

Strona 8

10 ProLink® II Software for Micro Motion® TransmittersInstallation and SetupTable 2-1 Transmitter terminals for ProLink II connectionsTransmitterTermi

Strona 9

Installation and Use Manual 11Installation and SetupProLink II Setup Transmitter StartupUsing ProLink IIBefore You Begin2.5.1 Connection diagramsUse t

Strona 10 - Before You Begin

12 ProLink® II Software for Micro Motion® TransmittersInstallation and SetupFigure 2-2 HART/Bell 202 temporary connection to RFT9739 field-mount and R

Strona 11

Installation and Use Manual 13Installation and SetupProLink II Setup Transmitter StartupUsing ProLink IIBefore You BeginFigure 2-4 HART/Bell 202 conne

Strona 12 - Transmitters

© 2009 Micro Motion, Inc. All rights reserved. The Micro Motion and Emerson logos are trademarks and service marks of Emerson Electric Co. Micro Motio

Strona 13 - Installation and Setup

14 ProLink® II Software for Micro Motion® TransmittersInstallation and SetupFigure 2-5 Model 1700/2700 I.S. transmitters: Resistance and voltage requi

Strona 14

Installation and Use Manual 15Installation and SetupProLink II Setup Transmitter StartupUsing ProLink IIBefore You BeginFigure 2-7 Modbus/RS-485 conne

Strona 15

16 ProLink® II Software for Micro Motion® TransmittersInstallation and SetupFigure 2-8 Modbus/RS-485 temporary connection to the service portFigure 2-

Strona 16 - Transmitter

Installation and Use Manual 17Installation and SetupProLink II Setup Transmitter StartupUsing ProLink IIBefore You BeginFigure 2-10 Modbus/RS-485 conn

Strona 17 - 2.5.1 Connection diagrams

18 ProLink® II Software for Micro Motion® TransmittersInstallation and SetupFigure 2-12 Modbus/RS-485 connection to RS-485 terminals on MVD Direct Con

Strona 18 - 12 ProLink

Installation and Use Manual 19Installation and SetupProLink II Setup Transmitter StartupUsing ProLink IIBefore You Begin• If you use any other connect

Strona 19

20 ProLink® II Software for Micro Motion® TransmittersInstallation and SetupTable 2-4 Default communication parameters for Series 1000/2000/3000 trans

Strona 20 - HART/Bell 202 connections

Installation and Use Manual 21Installation and SetupProLink II Setup Transmitter StartupUsing ProLink IIBefore You Begin2.7 Obtain and configure a sit

Strona 21

22 ProLink® II Software for Micro Motion® TransmittersInstallation and SetupFigure 2-13 License windowc. Enter the site key into the Site Key textbox,

Strona 22

Installation and Use Manual 23Installation and SetupProLink II Setup Transmitter StartupUsing ProLink IIBefore You Begin2.9 Troubleshooting the ProLin

Strona 23

Installation and Use Manual iContentsChapter 1 Before You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.1 About

Strona 24

24 ProLink® II Software for Micro Motion® TransmittersInstallation and Setup8. Try adding resistance to the connection. • For HART connections, refer

Strona 25 - Parameter Option

Installation and Use Manual 25ProLink II Setup Transmitter StartupUsing ProLink IIBefore You BeginChapter 3Using ProLink II Software3.1 OverviewThis c

Strona 26 - 20 ProLink

26 ProLink® II Software for Micro Motion® TransmittersUsing ProLink II Software• Service port connections:- Service ports use standard connection para

Strona 27

Installation and Use Manual 27Using ProLink II SoftwareProLink II Setup Transmitter StartupUsing ProLink IIBefore You BeginFigure 3-1 Connect to Densi

Strona 28 - OK as required by the

28 ProLink® II Software for Micro Motion® TransmittersUsing ProLink II SoftwareNotes: • Due to the design of HART protocol, connections made using HAR

Strona 29

Installation and Use Manual 29Using ProLink II SoftwareProLink II Setup Transmitter StartupUsing ProLink IIBefore You BeginTo start configuring your t

Strona 30

30 ProLink® II Software for Micro Motion® TransmittersUsing ProLink II SoftwareFigure 3-4 Installed Options window3.6 Viewing process dataProLink II p

Strona 31 - Using ProLink II Software

Installation and Use Manual 31Using ProLink II SoftwareProLink II Setup Transmitter StartupUsing ProLink IIBefore You BeginTo enable inventory reset:1

Strona 32 - 26 ProLink

32 ProLink® II Software for Micro Motion® TransmittersUsing ProLink II Software3.8 Viewing meter statusProLink II allows you to view a variety of stat

Strona 33

Installation and Use Manual 33Using ProLink II SoftwareProLink II Setup Transmitter StartupUsing ProLink IIBefore You Begin3.9 Viewing and acknowledgi

Strona 34 - Commissioning Wizard

ii ProLink® II Software for Micro Motion® TransmittersContents3.10 Managing the ProLink II license . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 35

34 ProLink® II Software for Micro Motion® TransmittersUsing ProLink II SoftwareFigure 3-7 Alarm Log window3.9.2 Acknowledging alarmsTo acknowledge an

Strona 36 - 30 ProLink

Installation and Use Manual 35Using ProLink II SoftwareProLink II Setup Transmitter StartupUsing ProLink IIBefore You Begin3.10.1 Transferring to same

Strona 37

36 ProLink® II Software for Micro Motion® Transmitters

Strona 38 - 32 ProLink

Installation and Use Manual 37ProLink II Setup Transmitter StartupUsing ProLink IIBefore You BeginChapter 4Initial Transmitter Startup Procedures4.1 O

Strona 39

38 ProLink® II Software for Micro Motion® TransmittersInitial Transmitter Startup ProceduresFigure 4-1 Loop test procedure4.3 Trimming the milliamp (m

Strona 40 - 34 ProLink

Installation and Use Manual 39Initial Transmitter Startup ProceduresProLink II Setup Transmitter StartupUsing ProLink IIBefore You Begin ProLink II Se

Strona 41

40 ProLink® II Software for Micro Motion® TransmittersInitial Transmitter Startup ProceduresFigure 4-3 Milliamp trim wizard – Screen 2If the adjusted

Strona 42 - 36 ProLink

Installation and Use Manual 41Initial Transmitter Startup ProceduresProLink II Setup Transmitter StartupUsing ProLink IIBefore You Begin ProLink II Se

Strona 43 - Chapter 4

42 ProLink® II Software for Micro Motion® TransmittersInitial Transmitter Startup ProceduresFigure 4-4 Zeroing 4. Change the Zero Time if necessary. Y

Strona 44

Installation and Use Manual 43Meter Verification Transmitter TerminalsData LoggerTransmitter ConfigurationChapter 5Transmitter Configuration, Characte

Strona 45

Installation and Use Manual iiiContentsAppendix B Configuring the Discrete Batch Application . . . . . . . . . . . . . . . . . . 73B.1 About this ap

Strona 46 - 40 ProLink

44 ProLink® II Software for Micro Motion® TransmittersTransmitter Configuration, Characterization, and Calibration5.2.2 Loading a configuration file t

Strona 47

Installation and Use Manual 45Transmitter Configuration, Characterization, and CalibrationMeter Verification Transmitter TerminalsData LoggerTransmitt

Strona 48 - 42 ProLink

46 ProLink® II Software for Micro Motion® TransmittersTransmitter Configuration, Characterization, and Calibration5.3.1 Using the Gas Unit Configurato

Strona 49 - Chapter 5

Installation and Use Manual 47Transmitter Configuration, Characterization, and CalibrationMeter Verification Transmitter TerminalsData LoggerTransmitt

Strona 50 - 44 ProLink

48 ProLink® II Software for Micro Motion® TransmittersTransmitter Configuration, Characterization, and CalibrationFigure 5-2 Sample calibration tags –

Strona 51

Installation and Use Manual 49Transmitter Configuration, Characterization, and CalibrationMeter Verification Transmitter TerminalsData LoggerTransmitt

Strona 52 - 46 ProLink

50 ProLink® II Software for Micro Motion® TransmittersTransmitter Configuration, Characterization, and CalibrationFigure 5-4 ProLink II calibration op

Strona 53 - T- Se ri es O t h e r

Installation and Use Manual 51Transmitter Configuration, Characterization, and CalibrationMeter Verification Transmitter TerminalsData LoggerTransmitt

Strona 54 - Newer tag Older tag

52 ProLink® II Software for Micro Motion® TransmittersTransmitter Configuration, Characterization, and CalibrationFigure 5-5 D1 and D2 density calibra

Strona 55 - Flow FCF X.XXXX FT X.XX

Installation and Use Manual 53Transmitter Configuration, Characterization, and CalibrationMeter Verification Transmitter TerminalsData LoggerTransmitt

Strona 56 - 50 ProLink

iv ProLink® II Software for Micro Motion® Transmitters

Strona 57

54 ProLink® II Software for Micro Motion® TransmittersTransmitter Configuration, Characterization, and Calibration5.5.3 Temperature calibrationTempera

Strona 58

Installation and Use Manual 55Transmitter Configuration, Characterization, and CalibrationMeter Verification Transmitter TerminalsData LoggerTransmitt

Strona 59

56 ProLink® II Software for Micro Motion® TransmittersTransmitter Configuration, Characterization, and Calibration5. If you will use a static pressure

Strona 60 - 5.5.3 Temperature calibration

Installation and Use Manual 57Transmitter Configuration, Characterization, and CalibrationMeter Verification Transmitter TerminalsData LoggerTransmitt

Strona 61

58 ProLink® II Software for Micro Motion® Transmitters

Strona 62 - 56 ProLink

Installation and Use Manual 59Meter Verification Transmitter TerminalsData LoggerTransmitter ConfigurationChapter 6Meter Verification6.1 OverviewMeter

Strona 63

60 ProLink® II Software for Micro Motion® Transmitters

Strona 64 - 58 ProLink

Installation and Use Manual 61Meter Verification Transmitter TerminalsData LoggerTransmitter ConfigurationChapter 7Data Logger7.1 OverviewThe Data Log

Strona 65 - Meter Verification

62 ProLink® II Software for Micro Motion® TransmittersData LoggerNote: The log file can become very large if you choose Time Interval and log for a lo

Strona 66 - 60 ProLink

Installation and Use Manual 63Data LoggerMeter Verification Transmitter TerminalsData LoggerTransmitter ConfigurationWhile Data Logger is running, you

Strona 67 - Data Logger

Installation and Use Manual 1ProLink II Setup Transmitter StartupUsing ProLink IIBefore You BeginChapter 1Before You Begin1.1 About this manualThis ma

Strona 68 - 62 ProLink

64 ProLink® II Software for Micro Motion® Transmitters

Strona 69

Installation and Use Manual 65Meter Verification Transmitter TerminalsData LoggerTransmitter ConfigurationAppendix ATransmitter Terminal ReferenceA.1

Strona 70 - 64 ProLink

66 ProLink® II Software for Micro Motion® TransmittersTransmitter Terminal ReferenceFigure A-2 RFT9712 and IFT9701/9793 transmitters Figure A-3 Model

Strona 71 - Appendix A

Installation and Use Manual 67Transmitter Terminal ReferenceMeter Verification Transmitter TerminalsData LoggerTransmitter ConfigurationFigure A-4 Mod

Strona 72 - 66 ProLink

68 ProLink® II Software for Micro Motion® TransmittersTransmitter Terminal ReferenceFigure A-6 Model 2400S transmitters with analog outputsUser interf

Strona 73

Installation and Use Manual 69Transmitter Terminal ReferenceMeter Verification Transmitter TerminalsData LoggerTransmitter ConfigurationFigure A-7 Mod

Strona 74 - 68 ProLink

70 ProLink® II Software for Micro Motion® TransmittersTransmitter Terminal ReferenceFigure A-9 Series 3000 transmitters Series 3000 panel-mountSeries

Strona 75

Installation and Use Manual 71Transmitter Terminal ReferenceMeter Verification Transmitter TerminalsData LoggerTransmitter ConfigurationFigure A-10 Co

Strona 76 - 70 ProLink

72 ProLink® II Software for Micro Motion® Transmitters

Strona 77 - Figure A-10 Core processor

Installation and Use Manual 73Index Discrete BatchAppendix BConfiguring the Discrete Batch ApplicationB.1 About this appendixThis appendix explains

Strona 78 - 72 ProLink

2 ProLink® II Software for Micro Motion® TransmittersBefore You Begin1.2.2 Uses of ProLink IIUsing ProLink II, you can:• Perform initial transmitter s

Strona 79 - Appendix B

74 ProLink® II Software for Micro Motion® TransmittersConfiguring the Discrete Batch ApplicationFigure B-1 Discrete batch configuration panel3. Click

Strona 80 - 74 ProLink

Installation and Use Manual 75Configuring the Discrete Batch ApplicationIndex Discrete Batch Index Discrete Batch Index Discrete Batch Index D

Strona 81

76 ProLink® II Software for Micro Motion® TransmittersConfiguring the Discrete Batch ApplicationB.3.1 Flow sourceThe flow source specifies the flow va

Strona 82 - Setting Default Description

Installation and Use Manual 77Configuring the Discrete Batch ApplicationIndex Discrete Batch Index Discrete Batch Index Discrete Batch Index D

Strona 83

78 ProLink® II Software for Micro Motion® TransmittersConfiguring the Discrete Batch ApplicationOne-stage versus two-stage batchingIf Number of stages

Strona 84 - 78 ProLink

Installation and Use Manual 79Configuring the Discrete Batch ApplicationIndex Discrete Batch Index Discrete Batch Index Discrete Batch Index D

Strona 85

80 ProLink® II Software for Micro Motion® TransmittersConfiguring the Discrete Batch ApplicationB.3.4 Batch control methodsBatch control functions can

Strona 86 - 80 ProLink

Installation and Use Manual 81Configuring the Discrete Batch ApplicationIndex Discrete Batch Index Discrete Batch Index Discrete Batch Index D

Strona 87 - Figure B-3 Discrete Input tab

82 ProLink® II Software for Micro Motion® TransmittersConfiguring the Discrete Batch ApplicationInhibit Batch and Inhibit Totalizer processingIf the I

Strona 88 - Default

Installation and Use Manual 83Configuring the Discrete Batch ApplicationIndex Discrete Batch Index Discrete Batch Index Discrete Batch Index D

Strona 89

Installation and Use Manual 3Before You BeginProLink II Setup Transmitter StartupUsing ProLink IIBefore You Begin1.4 Determining your transmitter type

Strona 90 - 84 ProLink

84 ProLink® II Software for Micro Motion® TransmittersConfiguring the Discrete Batch ApplicationBatch management functions are shown at the top of the

Strona 91 - Index Discrete Batch

Installation and Use Manual 85Index Discrete BatchIndexAAdapaters 2Adapter-barrier 67Alarm log 33Alarm severityand status window 33Alarmsacknowledgi

Strona 92 - 86 ProLink

86 ProLink® II Software for Micro Motion® TransmittersIndexDiscrete eventsassignment 82in batch control 80Discrete inputsassignment 82in batch control

Strona 93

Installation and Use Manual 87IndexIndex Discrete Batchviewing and resetting inventories 30viewing process data 30viewing status 32viewing, starting

Strona 94 - 88 ProLink

88 ProLink® II Software for Micro Motion® Transmitters

Strona 96 - *20001909*

Micro Motion Inc. USAWorldwide Headquarters7070 Winchester CircleBoulder, Colorado 80301T +1 303-527-5200+1 800-522-6277F +1 303-530-8459Micro Motion