Emerson 1410 Instrukcja Obsługi Strona 132

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 222
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 131
FRU Information and Sensor Data Records
AXP 1410 Installation and Use (6806800H70D)
132
Hysteresis support Readable/Settable
Threshold access support Readable/Settable
Event message control Entire Sensor only
Readable threshold mask,
Settable threshold mask (bytes
19, 20)
0x3838 Critical and Non-Recoverable Thresholds
are Readable and Settable
Reading Type Unsigned
Critical and Non-Recoverable
thresholds
0x2D, 0x35, 0x3F (57, 67) Degrees C
Table 7-11 Sensor No. 34 FTM Temp 5
Feature Raw Value/Description Interpreted Value
Sensor Name FTM Temp 5
Device
Sensor Type 0x01 Temperature
Class 0x01 Threshold
Sensor Owner LUN 0x00
Entity ID 0x0A
Entity Instance 0x60
Rearm mode Auto
Hysteresis support Readable/Settable
Threshold access support Readable/Settable
Event message control Entire Sensor only
Readable threshold mask,
Settable threshold mask (bytes
19, 20)
0x3838 Critical and Non-Recoverable Thresholds
are Readable and Settable
Reading Type Unsigned
Critical and Non-Recoverable
thresholds
0x2D, 0x35, 0x3F (57, 67) Degrees C
Table 7-10 Sensor No. 33 FTM Temp 4 (continued)
Feature Raw Value/Description Interpreted Value
Przeglądanie stron 131
1 2 ... 127 128 129 130 131 132 133 134 135 136 137 ... 221 222

Komentarze do niniejszej Instrukcji

Brak uwag