FRU Information and Sensor Data Records
AXP 1410 Installation and Use (6806800H70D)
153
Board Product Name = Centellis 4000 Power Entry Module
Board Serial Number = XXXXXXX 7 digit Board S/N)
Board Part Number = 0106831D01C
FRU Programmer File ID = CENT4000_PEM.inf
Product Info Area:
Version = 1
Language Code = 25
Manufacturer Name = Emerson Network Power, Embedded Coputing
Product Name = PEM4000
Product Part / Model# = 0106823D01C
Product Version = Rev. 1.00
Product Serial Number = XXXXXX (6 digit assembly S/N)
Asset Tag =
FRU Programmer File ID = CENT4000_PEM.inf
7.3.2 E-Keying
The Power Entry Module does not have e-keyed backplane interfaces, and as a result the FRU
information for the PEM does not contain a PICMG Point-to-Point Connectivity Record.