Emerson 3051S Dokumentacja Strona 144

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 143
134
Reference Manual
00809-0100-4001, Rev JA
Appendix A: Reference Data
November 2012
Specifications and reference data
Integral Mount Primary Element
Standard Standard
S4
(6)
Assemble to Rosemount Annubar or Rosemount 1195 Integral Orifice
(With the primary element installed, the maximum operating pressure will equal the lesser of
either the transmitter or the primary element. Option is available for factory assembly to range 1–4
transmitters only)
Seal Assemblies
Standard Standard
S1
(6)
Assemble to one Rosemount 1199 seal
S2
(6)
Assemble to two Rosemount 1199 seals
All-Welded Seal Assemblies (for high vacuum applications)
Standard Standard
S0
(6)
One Seal, All-Welded System (Direct Mount Connection Type)
S7
(6)
One Seal, All-Welded System (Capillary Connection Type)
S8
(6)
Two Seals, All-Welded System (Capillary Connection Type)
S9
(6)
Two Seals, All-Welded System (One Direct Mount and One Capillary Connection Type)
Mounting Bracket
Standard Standard
B1 Traditional Flange Bracket for 2-in. Pipe Mounting, CS Bolts
B2 Traditional Flange Bracket for Panel Mounting, CS Bolts
B3 Traditional Flange Flat Bracket for 2-in. Pipe Mounting, CS Bolts
B4 Coplanar Flange Bracket for 2-in. Pipe or Panel Mounting, all SST
B7 B1 Bracket with Series 300 SST Bolts
B8 B2 Bracket with Series 300 SST Bolts
B9 B3 Bracket with Series 300 SST Bolts
BA SST B1 Bracket with Series 300 SST Bolts
BC SST B3 Bracket with Series 300 SST Bolts
Product Certifications
Standard Standard
C6 CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2
E2 INMETRO Flameproof