12
Rosemount 3051
September 2014
www.rosemount.com
Isolating diaphragm Process connection wetted parts material
2
(10)
316L SST 316L SST H
3
(10)
Alloy C-276 Alloy C-276 H
Sensor fill fluid
1 Silicone H
2
(9)
Inert H
Housing material Conduit entry size
A Aluminum ½–14 NPT H
B Aluminum M20 × 1.5 H
J SST ½–14 NPT H
K SST M20 × 1.5 H
P
(11)
Engineered polymer No conduit entries H
D
(12)
Aluminum G½
M
(12)
SST G½
Wireless options (requires wireless Output Code X and Engineered Polymer Housing Code P)
Wireless transmit rate, operating frequency, and protocol
WA3 User Configurable Transmit Rate, 2.4GHz WirelessHART H
Antenna and SmartPower
WP5 Internal Antenna, Compatible with Green Power Module (I.S. Power Module Sold Separately) H
HART Revision configuration (requires HART Protocol Output Code A)
HR5
(4)
Configured for HART Revision 5 H
HR7
(4)
Configured for HART Revision 7 H
Options (include with selected model number)
Extended product warranty
WR3 3-year limited warranty H
WR5 5-year limited warranty
H
PlantWeb control functionality
A01
(13)
FOUNDATION fieldbus Control Function Block Suite H
PlantWeb diagnostic functionality
DA0
(22)
Power Advisory HART Diagnostic H
D01
(13)
FOUNDATION fieldbus Diagnostics Suite H
Integral assembly
S5
(14)
Assemble to Rosemount 306 Integral Manifold H
Diaphragm seal assemblies
S1
(14)
Assemble to one Rosemount 1199 seal H
Mounting bracket
(15)
B4 Bracket for 2-in. Pipe or Panel Mounting, All SST H
Product certifications
E8 ATEX Flameproof and Dust Certification H
I1
(16)
ATEX Intrinsic Safety and Dust H
Table 2. 3051T In-Line Pressure Transmitter Ordering Information
H The Standard offering represents the most common options. The starred options (H) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Komentarze do niniejszej Instrukcji