34
Rosemount 3051
September 2014
www.rosemount.com
Transmitter output
A
(3)
4–20 mA with digital signal based on HART Protocol H
F FOUNDATION fieldbus Protocol H
W
(4)
PROFIBUS PA Protocol H
X
(5)
Wireless H
M
(6)
Low-Power 1-5 Vdc with Digital Signal Based on HART Protocol
Transmitter housing material Conduit entry size
A Aluminum
1
/2-14 NPT H
B Aluminum M20 x 1.5 H
J SST
1
/2-14 NPT H
K SST M20 x 1.5 H
P
(7)
Engineered polymer No conduit entries H
D
(8)
Aluminum G
1
/2
M
(8)
SST G
1
/2
Transmitter performance class
1 up to ±1.8% flow rate accuracy, 8:1 flow turndown, 5-year stability H
Wireless options (requires Wireless Output Code X and Engineered Polymer Housing Code P)
Wireless transmit rate, operating frequency, and protocol
WA3 User Configurable Transmit Rate, 2.4GHz WirelessHART H
Antenna and SmartPower
WP5 Internal Antenna, Compatible with Green Power Module (I.S. Power Module Sold Separately) H
HART revision configuration (requires HART Protocol Output Code A)
HR5
(3)
Configured for HART Revision 5 H
HR7
(3)
Configured for HART Revision 7 H
Options (include with selected model number)
Extended product warranty
WR3 3-year limited warranty H
WR5 5-year limited warranty H
Transmitter body/bolt material
GT High Temperature (850 °F / 454 °C)
Temperature sensor
RT
(9)
Thermowell and RTD
Optional connection
G1 DIN 19213 Transmitter Connection H
Pressure testing
P1
(10)
Hydrostatic Testing with Certificate
Special cleaning
P2 Cleaning for Special Services
PA Cleaning per ASTM G93 Level D (Section 11.4)
Material testing
V1 Dye Penetrant Exam
Table 5. Rosemount 3051CFP Integral Orifice Flowmeter Ordering Information
H The Standard offering represents the most common options. The starred options (H) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.