Product Data Sheet
00813-0100-4530, Rev AA
Catalog 2008 - 2009
Level-5
Rosemount 5300 Series
The transmitter is available with Intrinsically Safe
(1)
/
Non-Incendive or Explosionproof / Flameproof
approvals. A safety isolator such as a zener barrier
must be used for intrinsic safety. Refer to “Product
Certifications” on page 21 and “Ordering Information”
on page 32.
DISPLAY
Data can be read from the optional integral display or
remotely by using the Rosemount 751 Field Signal
Indicator for 4-20 mA / HART
®
(see Product Data
Sheet, document number 00813-0100-4378), or the
Rosemount 752 Remote Indicator for F
OUNDATION™
fieldbus ( see Product Data Sheet, document number
00813-0100-4377).
MEASUREMENT PARAMETERS
From one Rosemount 5300 Series radar transmitter
it is possible to receive multiple process variables.
See information on parameters and transmitter
models in the following table.
Rosemount 5301, 5302, and 5303 are described in
“Transmitter Housing” on page 6.
* Interface measurement only for fully submerged probe,
see page Level-12.
CONFIGURATION
Basic configuration can easily be done either with
Rosemount RadarMaster, a Rosemount 375 Field
Communicator, the AMS™ Suite, DeltaV
®
or any
other DD (Device Description) compatible host
system. For advanced configuration features and
extensive diagnostics, RadarMaster, or an alternative
host that supports enhanced EDDL (such as the
AMS Device Manager) is required.
RadarMaster is a user-friendly, Windows based
software package that provides easy configuration
and service for both F
OUNDATION™ fieldbus and
HART
®
. A wizard guides the user to enter the
required parameters for a basic configuration.
“Measure & Learn” functionality is accessed through
RadarMaster. It enables automatic suggestion of
level threshold values, thereby making tough
applications easy to configure.
RadarMaster also includes an echo curve with movie
feature, off-line configuration, logging and extensive
on-line help.
The Enhanced EDDL capabilities of the 5300 Series
also make it possible to view the echo curve from a
field communicator or AMS, and to initiate the
Measure-and-Learn functionality in the transmitter.
It is possible to view the echo curve from a Rosemount 375
Field Communicator.
(1) Fisco Intrinsic safety is available for Foundation™ field-
bus. See “Ordering Information” on page 32 for more
information on available approvals.
The optional HART
®
Tri-loop, HART-to-Analog signal
converter.
The integral display is easily
configured with Rosemount
RadarMaster or the
Rosemount 375 Field
Communicator. The user
can choose which variable
to display or if toggling
between different variables
should be applied.
5301 5302 5303
Level XXX
Distance to Level XXX
Interface Level (X)* X
Interface Distance (X)* X
Upper Layer Thickness X
Total Volume XXX
Upper Volume (X)* X
Lower Volume (X)* X
Fn