Emerson PMC-CGM Instrukcja Użytkownika Strona 45

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 66
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 44
Configure Parameters for Event Handling Access and Configuration
PMC-CGM Installation and Use (6806800D53C)
45
2 - Critical events and warnings are logged
3 - Critical events, warning and events are logged
4 - Everything is logged
Default value is (3).
7. Check the default value and adapt it if necessary.
8. Go to cgmSysEventTrapLevel object OID:.1.3.6.1.4.1.3656.8152.1.3.14.0.
Specifies up to which severity new event log entries are posted as a trap (using the
cgmLogEvent object).
0 - No events are posted
1 - Only critical events are posted
2 - Critical events and warnings are posted
3 - Critical events, warning and events are posted
4 - Everything is posted
Default value is (3).
9. Check the default value and adapt it if necessary.
Przeglądanie stron 44
1 2 ... 40 41 42 43 44 45 46 47 48 49 50 ... 65 66

Komentarze do niniejszej Instrukcji

Brak uwag