PMC-CGM Installation and Use (6806800D53C)
MIB Description cgmControl
48
.1.1.1.1.3 cgmInputFrequency Configures the input frequency:
0: 8 KHz
1: 1544 KHz / 2048 KHz, depending on E1/T1
operation.
3: 19.44 MHz
r/w
.1.1.1.1.4 cgmT0InputPriority This setting is applied to the protection partner
as well.
A priority value from 2 to 15 used by the T0 PLL
to select an input. A lower numerical value
means a higher priority. A value of 0 disables
the input, that means it will not be selected as
reference clock. A value of 1 cannot be set as
it is used for the master/slave synchronization
clock.
Default value is 0.
r/w
.1.1.1.1.5 cgmT4InputPriority Priority of frequency monitor (T4 Path). Lower
numerical values represent a higher priority
than greater values.
A value of 0 means that the input will never be
selected as active input.
Default value is 0.
r/w
.1.1.1.1.6 cgmInputState Indicates whether the input receives a valid
clock or not.
r/w
.1.1.1.1.7 cgmInputActivityMonitorEna Controls whether the activity monitor for this
input is enabled.
r/w
.1.1.1.1.8 cgmInputActivityMonitorState Reports the state of the activity monitor for this
input.
r
Table 5-3 Input Assignments
Instance cgmInputNumber cgmInputName
Default
cgmInputFrequency
2 3 BITS1 freqE1T1 (1)
3 4 BITS2 freqE1T1 (1)
6 7 REFA freq8K (0)
10 11 MS_SYNC freq8K (0)
11 12 REFB freq8K (0)
Table 5-2 cgmInputTable (continued)
OID MIB Object Description Access