Emerson 627W Arkusz Danych Strona 12

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 12
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 11
Bulletin 71.1:627W
The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their prospective owners. Fisher is a mark owned by Fisher Controls, Inc., a
business of Emerson Process Management.
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or
guarantees, express or implied, regarding the products or services described herein or their use or applicability. We reserve the right to modify or improve the designs or specications of such
products at any time without notice.
Emerson Process Management does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any Emerson
Process Management product remains solely with the purchaser.
©Emerson Process Management Regulator Technologies, Inc., 1994, 2009; All Rights Reserved
Industrial Regulators
Emerson Process Management
Regulator Technologies, Inc.
USA - Headquarters
McKinney, Texas 75069-1872 USA
Tel: 1-800-558-5853
Outside U.S. 1-972-548-3574
Asia-Pacic
Shanghai, China 201206
Tel: +86 21 2892 9000
Europe
Bologna, Italy 40013
Tel: +39 051 4190611
Middle East and Africa
Dubai, United Arab Emirates
Tel: +971 4811 8100
Natural Gas Technologies
Emerson Process Management
Regulator Technologies, Inc.
USA - Headquarters
McKinney, Texas 75069-1872 USA
Tel: 1-800-558-5853
Outside U.S. 1-972-548-3574
Asia-Pacic
Singapore, Singapore 128461
Tel: +65 6777 8211
Europe
Bologna, Italy 40013
Tel: +39 051 4190611
Gallardon, France 28320
Tel: +33 (0)2 37 33 47 00
TESCOM
Emerson Process Management
Tescom Corporation
USA - Headquarters
Elk River, Minnesota 55330-2445 USA
Tel: 1-763-241-3238
Europe
Selmsdorf, Germany 23923
Tel: +49 (0) 38823 31 0
For further information visit www.sherregulators.com
Specication Worksheet
Application:
Specic Use
Line Size
Fluid Type
Specic Gravity
Temperature
Does the Application Require Overpressure Protection?
Yes No
Pressure:
Maximum Inlet Pressure
Minimum Inlet Pressure
Differential Pressure
Set Pressure
Maximum Flow
Accuracy Requirements:
Less Than or Equal To:
5% 10% 20% 40%
Construction Material Requirements (if known):
Regulators Quick Order Guide
* * * Readily Available for Shipment
* * Allow Additional Time for Shipment
*
Special Order, Constructed from Non-Stocked Parts.
Consult your local Sales Ofce for Availability.
Availability of the product being ordered is determined by the component with the
longest shipping time for the requested construction.
Ordering Guide (continued)
Valve Disk (Select One)
Nitrile (NBR) (standard)***
Nylon (PA)***
Fluorocarbon (FKM) - water limited to 180°F (82°C)**
Ethylenepropylene (EPDM)**
Spring Range (Select One)
Type 627W
10 to 20 psig (0,69 to 1,4 bar)***
15 to 40 psig (1,0 to 2,8 bar)***
35 to 80 psig (2,4 to 5,5 bar)***
70 to 150 psig (4,8 to 10,3 bar)***
Type 627WH
140 to 250 psig (9,7 to 17,2 bar)***
240 to 500 psig (16,5 to 34,5 bar)***
PTFE Diaphragm Protector (Optional)
Yes
Pressure Registration (Select One)
Internal***
External***
Przeglądanie stron 11