Emerson Rosemount 644h Instrukcja Obsługi Strona 15

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 68
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 14
2-5
EN
Rosemount Inc
Head Mount Transmitter with DIN Plate Style Sensor
Refer to Volume 2 of the Rosemount Sensors Product Data Sheet (document
number 00813-0101-2654) for complete sensor and mounting accessory
information.
To complete the assembly, follow the steps described below.
1. Attach the thermowell to the pipe or process container wall. Install and
tighten the thermowell before applying pressure.
2. Set the transmitter failure mode switch (see Figure 2-11 on page 2-11).
3. Assemble the transmitter to the sensor. Push the transmitter mounting
screws through the sensor mounting plate and insert the snap rings
(optional, part number 00644-4432-0001) into the groove of each transmitter
mounting screw.
4. Insert the transmitter-sensor assembly into the connection head. Thread the
transmitter mounting screw into the connection head mounting holes.
5. Assemble the extension to the connection head. Insert the assembly into
the thermowell.
6. Attach a cable gland into the shielded cable.
7. Insert the shielded cable leads into the connection head through the cable
entry. Connect and tighten the cable gland.
8. Connect the shielded cable leads to the transmitter power terminals. Avoid
contact with leads and terminals.
9. Install and tighten the connection head cover. Enclosure covers must be fully
engaged to meet explosion-proof requirements.
Figure 2-4. Typical Model 644H Transmitter Mounting Configuration Using Integral
Mount Sensor and Assembly
644-0000B04A
Model 644H
Transmitter
Integral Mount Sensor
with Flying Leads
Threaded Extension
Threaded Thermowell
Connection Head