A-7
EN
Rosemount Inc
CE Electromagnetic Compatibility Compliance Testing
The Models 644H and 644R meet all requirements listed under IEC 61326:
Amendment 1, 1998.
Self Calibration
The analog-to-digital measurement circuitry automatically self-calibrates for each
temperature update by comparing the dynamic measurement to extremely stable
and accurate internal reference elements.
Electrical Connections
Materials of Construction
The Model 644H installs in a connection head or universal head mounted directly
on a sensor assembly, apart from a sensor assembly using a universal head, or to a
DIN rail using an optional mounting clip. The Model 644R mounts directly to a
wall or to a DIN rail.
Weight
Enclosure Ratings (Model 644H)
Option codes J5 and J6 are NEMA 4X, IP66, and IP68.
Option code J6 is CSA Enclosure Type 4X
Power and Sensor Terminals
Model 644H Compression screws permanently fixed to
terminal block
Clips permanently fixed to
terminal block
Model 644R: Compression screw permanently fixed to
front panel
Clips permanently fixed to front panel
WAGO
®
spring clamp terminals are optional (option code G5)
Construction Material for the Electronics Housing and Terminal Block
Model 644H
Noryl
®
glass reinforced
Model 644R:
Lexan
®
polycarbonate
Code Options Add
(1)
(1) All weights are in grams (ounces).
Model 644H Head Mount 78 (2.75)
M5 LCD Meter 34 (1.20)
J5, J6 Universal Head, Standard Cover 520 (18.43)
J5, J6 Universal Head, Meter Cover 604 (21.27)
Model 644R Rail Mount 173 (6.10)