Reference Manual
00809-0600-4026, Rev BA
December 2011
Rosemount Process Radar
2-16
10. This step is not applicable for FOUNDATION fieldbus. The parameters are
entered in the AI-block instead.
Fast Key Sequence [2, 1, 6]
For HART communication, choose Primary Variable, PV.
Specify the analog output range by setting the Upper Range Value (20
mA) and the Lower Range Value (4 mA) to the desired corresponding
level values.
The Alarm Mode specifies the output state when a measurement error
occurs. Choose between the following:
High: 21.75 mA (standard) or 22.5 mA (Namur)
Low: 3.75 mA (standard) or 3.6 mA (Namur)
Freeze: the output current is set to the last valid value at the time when
the error occurs.
Click Next.
11. Continue with Steps 2 to 5 in the Guided Setup window:
Step 2: Device specific setup might advise you to make further
configurations. Fast Key Sequence [2, 1, 7, 2].
Step 3: Restart the device to make sure all configuration changes are
properly activated.
Step 4: View live values from the device to verify that the transmitter
works correctly.
Step 5: Make a complete backup of the device.
12. The Basic Configuration with the Radar Master Wizard is now finished.
Proceed with the Device Specific Setup to see which additional
configuration is needed. It will recommend to calibrate Vapor
Compensation or Probe End Projection, or to perform a Trim Near Zone
if it needs to be done. For further information, see the Rosemount 5300
Series Reference Manual (Document No. 00809-0100-4530).
For Signal Quality Metrics information and further configuration, see the
Rosemount 5300 Series Reference Manual (Document No.
00809-0100-4530).
Step 1: Run Wizard
Step 3: Restart the device
Step 4: View live values from the device
Step 5: Make a complete backup of the device
Step 2: Device specific setup