Reference Manual
00809-0600-4026, Rev BA
December 2011
Rosemount Process Radar
3-2
INSTALLATION &
CONFIGURATION
Step 1. Complete the QIG Follow the instructions provided in Section 2: 5300 Quick Installation Guide.
Step 2. Complete the
Basic Configuration
Basic Configuration Parameters
• HART/FF Address
• Device Tag
• Measurement Units
• Tank Geometry
Figure 3-1. Tank Geometry
• Probe Type
• Hold Off/Upper Null Zone
This parameter should only be changed if there are disturbing objects
close to the antenna, e.g. nozzle disturbances. No valid measurements
are possible above the Hold Off Distance.
• Measurement Mode
• Rapid Level Changes
• Dielectric Constant
• Volume Configuration
For volume calculations, you can choose one of the standard tank
shapes or the strapping option. Choose None if volume calculation is
not used.
• Analog Output (HART)
Tank Height
Hold Off/
Upper Null Zone
Product Level
Upper Reference Point
Lower Reference Point
Interface
Level
Probe
Length