125
Programming
Subroutine for Jogging the Axis into the Desired Position (Program 1)
‘Allow jogging until either the “Learn” input (DriveInput.1)
‘or the “Skip” input (DriveInput.2) goes ON.
Do While ((DriveInput.1=OFF) AND (DriveInput.2=OFF))
If (DriveInput.3=ON) Then ‘Jog+ if the Jog+ input is on
Jog.0.PlusInitiate ‘Vel=0.1in/s
Do While (DriveInput.3=ON)
If (DriveInput.5=ON) Then ‘DriveInput.5 = “Jog Fast”
Jog.0.Vel = 1.0 ‘in/s
Else
Jog.0.Vel = 0.1‘in/s
Endif
Loop
Jog.Stop ‘Stop jogging when the Jog+ input goes off.
Endif
If (DriveInput.4=ON) Then ‘Jog- if the Jog- input is on
Jog.0.MinusInitiate ‘Vel=0.1in/s
Do While (DriveInput.4=ON)
If (DriveInput.5=ON) Then ‘DriveInput.5 = “Jog Fast”
Jog.0.Vel = 1.0 ‘in/s
Else
Jog.0.Vel = 0.1 ‘in/s
Endif
Loop
Jog.Stop ‘Stop jogging when the Jog+ input goes off.
Endif
Loop
Playback Program (Program 2)
Home.0.Initiate ‘Sensor,Offset=0.000in,Vel=-10in/s
Do While (TRUE) ‘Repeat until the program is halted
Index.1.Initiate ‘Absolute,Posn=1.000in,Vel=5in/s
Wait For InPosn
DriveOutput.1=ON ‘Turn on DriveOutput.1 for 1 second
Wait For Time 1.000 ‘seconds
DriveOutput.1=OFF
Index.2.Initiate ‘Absolute,Posn=20.000in,Vel=7in/s
Wait For InPosn
DriveOutput.1=ON ‘Turn on DriveOutput.1 for 1 second
Wait For Time 1.000 ‘seconds
DriveOutput.1=OFF
Index.3.Initiate ‘Absolute,Posn=5.250in,Vel=10in/s
Wait For InPosn
DriveOutput.1=ON ‘Turn on DriveOutput.1 for 1 second
Wait For Time 1.000 ‘seconds
DriveOutput.1=OFF
Loop