Emerson Epsilon EP Drive 400518-01 Instrukcja Instalacji Strona 185

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 240
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 184
173
Quick Start for an FM-4 Module
Enable Following Error – Enable this check box.
Following Error Limit – The example uses a limit of 0.25 Inches.
Enable Software Travel Limits – Enable this check box.
Software Travel Limit + and - - If the position feedback ever exceeds these values when traveling in a positive or negative
direction, the motor will come to a stop at the Travel Limit Decel rate defined on the Ramps view.
Tuning View
This example application has an inertia mismatch of 3.5:1 and has been entered as seen in Figure 112.
Figure 112: Tuning View
Making Assignments
Using this process, three individual assignments are made. The example application wants to turn on an output when each
index completes. Therefore, Index Complete sources will be assigned to the hardware Output destinations. Figure 113 shows
this process.
Przeglądanie stron 184
1 2 ... 180 181 182 183 184 185 186 187 188 189 190 ... 239 240

Komentarze do niniejszej Instrukcji

Brak uwag