Epsilon EP-P Drive and FM-3/4 Module Reference Manual
Parameters Not Matching List
This list is part of the User Defined Motor Name Conflict dialog box and displays the parameter value(s) from the Motor
Parameters column that do not match the equivalent parameter value in either the motor.ddf or stdmotor.ddf files, for the
motor with the matching name.
This helps the user to determine whether they wish to overwrite, cancel, or create a new motor with this Save .ddf Values
operation.
User Units View
The User Units View is used to scale the desired application units into known values. All information for distance, velocity,
and accel/decel units are set up here and used throughout the system setup.
By selecting User Units in the Hierarchy Tree, the User Units View will appear on the right (see Figure 40).
Figure 40: User Units View
Distance Group
Units Name
This is a 10-character name for the distance user units the user wants to use in the application.
Decimal Places
The number of decimal places set in this parameter determines the number of digits after the decimal point used in all distance
and position parameters throughout the configuration. Using a high number of decimal places will improve position
resolution, but will also limit the range of absolute position. You can select from zero to six decimal places of accuracy.
Note
When the number of decimal places are changed in an existing configuration file the Index accel and decel parameters
need to be checked.
Scaling
A Characteristic Distance and Length must be established to allow the device to scale user units back to actual motor
revolutions. This scaling factor is as follows:
Scaling
Characteristic Distance
Characteristic Length
-------------------------------------------------------=