switch with a Schraeder depressor (defla-
tor). Refer to the parts list in Appendix C.
Connect the blue “LPCO” leads to the low
pressure switch. Verify pressure setting on the
switch. When replacing the switch, use only
an Emerson Climate Technologies, Inc.
approved pressure switch with a
Schraeder depressor (deflator). Refer to the
parts list in Appendix C.
9. Refer to section 3.4, Compressor Naming, to edit
the E2 for changes to the compressor serial num-
ber.
5.4.2 Suggested Procedure for Replacement
of the Module (4D)
Refer to section 5.6.1 below, “Determine the
Replacement Module Part Number”. Note that the
failed module should be returned to the wholesaler to
prevent payment of a core charge.
To remove the old module:
1. Remove the terminal box cover (3 screws).
2. Remove the head cover (4 screws).
3. Unplug all harness connections that were under
the head cover shroud. Unplug the oil pressure
sensor harness at the oil pump.
4. Remove the front cover from the module. Unplug
the communication wire from the communication
board.
5. Remove screws (2) from the front box that hold
the rear guide shroud in place.
6. Remove the rear guide shroud.
7. Remove two mounting bracket nuts beneath the
front box. Front box may now be removed.
Remove
Nuts
Remove
Screws
Remove
Shroud
Remove
Head Cover
Screws
Remove
Terminal Box
Cover Screws
AE8-1337 R1