Reference Manual
00809-0100-4803, Rev DA
Appendix A: Reference Data
April 2013
Specifications and Reference Data
Digital Display
Standard Standard
M5 PlantWeb LCD Display
Special Procedures
Standard Standard
P1
(18)
Hydrostatic testing with certificate
P9
(2)
4500 psig (310 bar) static pressure limit
P0
(2)(19)
6092 psig (420 bar) static pressure limit
Expanded
P2
(13)
Cleaning for special services
P3
(13)
Cleaning for less than 1PPM chlorine/fluorine
Special Certifications
Standard Standard
Q4 Calibration Certificate
QP Calibration Certificate and Tamper Evident Seal
Q8 Material Traceability Certification per EN 10204 3.1B
Q16 Surface Finish Certification for Sanitary Remote Seals
QZ Remote Seal System Performance Calculation Report
Transient Protection
Standard Standard
T1 Transient terminal block
Conduit Electrical Connector
Standard Standard
GE
(20)
M12, 4-pin, Male Connector (eurofast
®
)
GM
(20)
A size Mini, 4-pin, Male Connector (minifast
®
)
Cold Temperature
Standard Standard
BRR -60 °F (-51 °C) Cold Temperature Start-up
Typical Model Number: 3051SMV 3 M 1 2 G 4 R 2 E12 A 1A B4 C2 M5
(1) Only available with DP range codes 2 and 3, 316L SST or Alloy C-276 isolating diaphragm and silicone fill fluid.
(2) Only available with Measurement Type codes 3 and 4.
(3) DP Range 0 is only available with traditional flange, 316L SST diaphragm material, and Bolting option L4.
(4) Required for Measurement Type codes 3 and 4.
(5) For Measurement Type 1 and 2 with DP range 1, absolute limits are 0.5 to 2000 psi (0,03 to 137,9 bar) and gage limits are -14.2 to 2000 psig
(-0,98 to 137,9 bar).
(6) Required for Measurement Type codes 2 and 4.
(7) Required for Measurement Type codes 1 and 3. RTD Sensor must be ordered separately.
(8) Materials of Construction comply with metallurgical requirements highlighted within NACE MR0175/ISO 15156 for sour oil field production environments. Environmental
limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
(9) Tantalum diaphragm material is only available for DP ranges 2-5.
(10) Assemble to” items are specified separately and require a completed model number.
(11) Consult an Emerson Process Management representative for performance specifications.
(12) For use with Flowmeters with integral RTDs.
(13) Not available with process connection option code A11.
(14) Transmitter is shipped with 316 SST conduit plug (uninstalled) in place of standard carbon steel conduit plug.
(15) Not available with M20 or G ½ conduit entry size.
(16) RTD cable not available with this option.
(17) Requires 316L SST diaphragm material, glass-filled PTFE O-ring (standard), and Process Connection code E12 or F12.
(18) Not available with DP range 0.
(19) Requires 316L SST or Alloy C-276 diaphragm material, assemble to Rosemount 305 Integral Manifold or DIN-compliant traditional flange process connection, and bolting
option L8. Limited to differential pressure ranges 2-5.
(20) Available with Intrinsically Safe approvals only. For FM Intrinsically Safe, Non-Incendive approval (option code I5), install in accordance with Rosemount drawing
03151-1009 to maintain outdoor rating (NEMA 4X and IP66).
Table 1. Rosemount 3051S Scalable MultiVariable transmitter ordering information
The Standard offering represents the most common options. The starred options () should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.