113
Parameter Descriptions
Enable Registration Window Index.#.RegistrationWindowEnable
This check box enables (if checked) the Registration Sensor valid Window. When active,
only registration marks that occur inside the registration window are seen as valid.
Window End Index.#.RegistrationWindowEnd
This parameter defines the end of the Registration Sensor Valid Window relative to start
position of this index. This is an unsigned value and is relative only to starting position of this
index. Index direction does not affect this parameter. The Registration Window start position
is greater than or equal to the Registration point and less than the Registration Window End
position. If a registration sensor is seen outside of this window (not between the WindowStart
and WindowEnd positions) then it will be ignored.
Window Start Index.#.RegistrationWindowStart
This parameter defines the start of the Registration Sensor Valid Window relative to start
position of this index. This is an unsigned value and is relative only to starting position of this
index. Index direction does not affect this parameter. The Registration Window start position
is greater than or equal to the Registration point and less than the Registration Window End
position. If a registration sensor is seen outside of this window (not between the WindowStart
and WindowEnd positions) then it will be ignored.
Registration Sensor Index.#.SensorTrigger
If registration to Sensor is selected, when this destination activates, motor position is captured
and is used as the registration point for registration type indexes.
Time Base Index.#.TimeBase
The time base selects either realtime, which allows velocities, acceleration and deceleration
to be based on real time, or synchronized, which allows for an external synchronization
signal.
Velocity Index.#.Vel
This parameter sets the target velocity of the specific index. The units for this parameter are
specified in the User Units Setup view. When an index is initiated, it will ramp up to this
velocity at the specified acceleration rate and run at speed until it decelerates to a stop
(assuming the index is not compounded).