FM-3 Programming Module Reference Manual
User Units View
The User Units View is used to scale the desired application units into known values. All
information for distance, velocity, and accel/decel units are set up here and used throughout
the system setup.
By selecting User Units in the hierarchy view, the User Units View will appear on the right
(see Figure 29).
Figure 29: User Units View
Distance Group
Units Name
This is a 10-character name for the distance user units you want to use in your application.
Decimal Places
The number of decimal places set in this parameter determines the number of digits after the
decimal point used in all distance and position parameters throughout the software. Using a
high number of decimal places will improve position resolution, but will also limit the
maximum position. You can select from zero to six decimal places of accuracy.