Setting Up Parameters
If the device is jogging with the Jog.PlusActivate destination active and the
Jog.MinusActivate destination activates, the motor will behave the same as if it would if
Jog.PlusActivate just deactivated.
The Stop destination (found under the Ramps group in the Assignments view) will override
the Jog operation and decelerate the motor to zero speed at the stop deceleration rate.
If the motor reaches a Travel Limit, you can Jog off the Travel Limit in the opposite direction.
(Use Jog.PlusActivate to move off a Travel Limit -).