118
FM-3 Programming Module Reference Manual
ModuleOutput Enable Force ModuleOutput.#.ForceEnable
If ModuleOutput.#.ForceEnable is activated, then the state of the ModuleOutput.#.Force bit
will override the current output state.
ModuleOutput Name ModuleOutput.#.Name
User assigned name to the hardware output.
ModuleOutput State ModuleOutput.#State
This destination sets the current state of an output line.
Module Serial Number ModuleSerialNumber
This is the FM-3 module serial number.
Motor Type MotorType
This parameter is used to select the motor type.
Name
User name for this FM-3 axis can have a length up to 12 characters. This can be used to help
differentiate setup files.
PLS Direction PLS.#.Direction
This parameter specifies the direction of motion that a particular PLS output will function. If
set to Both, the PLS will activate regardless of whether the axis is moving in the positive or
negative direction. If set to Plus, the PLS will activate only when the axis is moving in the
positive direction. If set to Minus, the PLS will activate only when the axis is moving in the
negative direction. A flying cutoff or flying shear application may use this feature to activate
the PLS to fire the knife only when the axis is moving in the positive direction.
PLS Off Point PLS.#.OffPosn
PLS.#.Status will be active when the selected source position is between the PLS.#.OnPosn
and the PLS.#.OffPosn. The terms On and Off assume you are traveling in a positive
direction. Assume that the PLS.#.Direction is set to "Both". When traveling in the positive
direction and the position feedback reaches the OnPosn, the PLS.#.Status will activate. As the
motor continues in the same direction, the PLS.#.Status will deactivate when feedback
position reaches or exceeds the OffPosn. If motor travel changes to the negative direction,
the PLS.#.Status will activate when position feedback reaches the OffPosn, and will
Komentarze do niniejszej Instrukcji