Setting Up Parameters
Tuning View
The Tuning View allows you to modify tuning parameters based on specific application
information.
By selecting Tuning in the hierarchy view, the Tuning View will appear in the right (see
Figure 35). The right part of the screen is divided into groups. An explanation of the groups
and their functions is provided below.
For help on calculating tuning parameters and more in-depth tuning information, turn to
“Tuning Procedures” on page157.
Figure 35: Tuning View
Load Group
Inertia Ratio
Inertia Ratio specifies the load to motor inertia ratio and has a range of 0.0 to 50.0. If the exact
inertia is unknown, a conservative approximate value should be used. If you enter an inertia
value higher than the actual inertia, the resultant motor response will tend to be more
oscillatory.