7
Operational Overview
Each jog has its own acceleration and deceleration ramp along with a specified velocity.
Jogging has no distance parameter associated with it. If trying to move a specific distance
or to a known position, then an index is used.
Jogging in the opposite direction will move off a travel limit (use Jog + to move off a Travel
Limit -).
Figure 5: Jog Tab
How Home Works
The Home is used in applications in which the axis must be precisely aligned with some part
of the machine. The Home is initiated in one of three ways: with the Initiate Destination
function found in the Assignments view, through a program, or with the Online tab. A Home
or Define Home is required to set the Absolute Position Valid so that any index to absolute
position can work.
The FM-3 can home the motor to an external sensor, the motor’s encoder marker pulse, or to
a sensor and then to the encoder marker pulse.