26 Transmitter Configuration and Use: Series 1000 and 2000 Transmitters
Connecting with the 275 HART Communicator or 375 Field Communicator continued
2. Connect the Communicator leads to the transmitter’s primary mA output terminals:
• Model 1700/2700 transmitters: terminals 1 and 2 (see Figure 4-1)
• Model 1500/2500 transmitters: terminals 21 and 22 (see Figure 4-2)
3. The Communicator must be connected across a resistance of 250–600 Ω. Add resistance to the
connection. See Figure 4-1.
Figure 4-1 Connecting to communication terminals – Model 1700/2700 transmitters
Figure 4-2 Connecting to communication terminals – Model 1500/2500 transmitters
Communicator
250–600 Ω
resistance
VDC (IS transmitters only)
See the transmitter installation manual
for voltage and resistance values
1
2
–
+
250–600 Ω
resistance
+–
Communicator