Emerson MICRO MOTION 2700 Instrukcja Instalacji Strona 47

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 46
Transmitter Configuration and Use: Series 1000 and 2000 Transmitters 37
Flowmeter Startup continued
Required Configuration Optional ConfigurationUsing the TransmitterFlowmeter Startup
5.4.2 Milliamp output trim with a Communicator
See Figure 5-6 for the mA output trim procedure.
Note the following:
If you are trimming the primary mA output, the HART/Bell202 signal to the
Communicator will affect the reading. Disconnect the Communicator before
reading the output, then reconnect and resume the trim, after taking the
reading.
Any trimming performed on the output should not exceed ± 200 microamps.
If more trimming is required, contact Micro Motion customer support.
The receiving device value that you enter in the Communicator can contain
up to two decimal places.
Figure 5-6 Communicator – mA output trim procedure
Model 1500 AN
Model 1700 AN
Model 1700 IS
Model 2500 CIO
Model 2700 AN
Model 2700 IS
Model 2700 CIO
Read mA output at
receiving device
Equal?
Enter receiving device
value at
Communicator
Read mA output at
receiving device
Trim Analog Out 1
Trim Analog Out 2
No
ENTER
Yes
ENTER
OK
ENTER
Read mA output at
receiving device
OK
4 mA trim 20 mA trim
Diag/Service
On-Line Menu
Read mA output at
receiving device
Equal?
Enter receiving device
value at
Communicator
No
ENTER
ENTER
Yes
ENTER
Przeglądanie stron 46