Transmitter Configuration and Use: Series 1000 and 2000 Transmitters 73
Using the Transmitter continued
Required Configuration Optional ConfigurationUsing the TransmitterFlowmeter Startup
Alarms in the alarm queue are arranged according to priority. To view specific alarms in the queue:
1. Activate and hold
Scroll and Select simultaneously until the words SEE ALARM appear on
the screen. See Figure 7-1.
2.
Select.
3. If the alternating words
ACK ALL appear, Scroll.
4. If the words
NO ALARM appear, go to Step 6.
5.
Scroll to view each alarm in the queue. See Section 10.11 for an explanation of the alarm
codes reported by the display.
6.
Scroll until the word EXIT appears.
7.
Select.
7.6.3 Using ProLink II
To view status and alarms with ProLink II software:
1. Click
ProLink.
2. Select
Status.
3. The status indicators are divided into three categories: Critical, Informational, and
Operational. To view the indicators in a category, click on the tab.
• A tab is red if one or more status indicators in that category is on.
• Within the tabs, current status alarms are shown by red status indicators.
7.6.4 Using the Communicator
To view status and alarms with a Communicator:
1. Press
1.
2. Select
View Status.
3. Press
OK to scroll through the list of current alarms.
Table 7-2 Priorities reported by the Model 1700/2700 status LED
Status LED state Alarm priority
Green No alarm—normal operating mode
Flashing green
(1)
(1) If the display alarm menu has been disabled, alarms cannot be acknowledged. In this case, the status LED will never flash.
Unacknowledged corrected condition
Yellow Acknowledged low severity alarm
Flashing yellow
(1)
Unacknowledged low severity alarm
Red Acknowledged high severity alarm
Flashing red
(1)
Unacknowledged high severity alarm