Reference Manual
00809-0200-4801, Rev CA
July 2010
Rosemount 3051S
B-4
MultiVariable Flow Performance
(1)
(1) Flow performance specifications assume device is configured for full compensation of static pressure, process temperature, density, viscosity, gas
expansion, discharge coefficient, and thermal correction variances over a specified operating range.
Mass, Energy, Actual Volumetric, and Totalized Flow Reference Accuracy
Models Ultra for Flow Classic MV
3051SMV
(2)
(2) Uncalibrated differential producer (0.2 < beta < 0.6 Orifice) installed per ASME MFC 3M or ISO 5167-1. Uncertainties for discharge coefficient, producer
bore, tube diameter, and gas expansion factor as defined in ASME MFC 3M or ISO 5167-1. Reference accuracy does not include RTD sensor accuracy.
DP Ranges 2-3 ±0.65% of Flow Rate over a 14:1 flow range
(200:1 DP range)
±0.70% of Flow Rate over 8:1 flow range
(64:1 DP range)
DP Range 1 Not Available ±0.90% of Flow Rate over 8:1 flow range
(64:1 DP range)
Annubar Flowmeter (3051SFA)
Ranges 2-3 ±0.85% of flow rate at 8:1 flow turndown ±0.80% of flow rate at 14:1 flow turndown
Compact Conditioning Orifice Flowmeter (3051SFC_C)
Ranges 2-3
= 0.4 ±0.60% of flow rate at 8:1 flow turndown ±0.55% of flow rate at 14:1 flow turndown
= 0.65 ±1.05% of flow rate at 8:1 flow turndown ±1.00% of flow rate at 14:1 flow turndown
Compact Orifice Flowmeter
(3)
(3051SFC_P)
(3) For smaller line sizes, see the Rosemount Compact Orifice Flowmeter Series Product Data Sheet (document number 00813-0100-4810).
Ranges 2-3
= 0.4 ±1.30% of flow rate at 8:1 flow turndown ±1.25% of flow rate at 14:1 flow turndown
= 0.65 ±1.30% of flow rate at 8:1 flow turndown ±1.25% of flow rate at 14:1 flow turndown
Integral Orifice Flowmeter (3051SFP)
Ranges 2-3
< 0.1 ±2.55% of flow rate at 8:1 flow turndown ±2.50% of flow rate at 14:1 flow turndown
0.1 < < 0.2 ±1.35% of flow rate at 8:1 flow turndown ±1.30% of flow rate at 14:1 flow turndown
0.2 < < 0.6 ±0.85% of flow rate at 8:1 flow turndown ±0.80% of flow rate at 14:1 flow turndown
0.6 < < 0.8 ±1.55% of flow rate at 8:1 flow turndown ±1.50% of flow rate at 14:1 flow turndown
Komentarze do niniejszej Instrukcji