Emerson 3051S Dokumentacja Strona 135

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 134
Reference Manual
00809-0200-4801, Rev CA
July 2010
B-5
Rosemount 3051S
Uncompensated Flow
Performance
Long Term Stability
Pressure
Process Temperature
(1)
Flow performance specifications assume the device only uses DP readings without pressure and temperature
compensation.
Models Ultra Classic Ultra for Flow
Annubar Flowmeter (3051SFA)
Ranges 2-3 ±0.85% of flow rate at 8:1 flow
turndown
±0.9% of flow rate at 8:1 flow
turndown
±0.80% of flow rate at 14:1 flow
turndown
Compact Conditioning Orifice Flowmeter (3051SFC_C)
Ranges 2-3
= 0.4 ±0.85% of flow rate at 8:1 flow
turndown
±1.05% of flow rate at 8:1 flow
turndown
±0.80% of flow rate at 14:1 flow
turndown
= 0.65 ±1.20% of flow rate at 8:1 flow
turndown
±1.35% of flow rate at 8:1 flow
turndown
±1.15% of flow rate at 14:1 flow
turndown
Compact Orifice Flowmeter
(3)
(3051SFC_P)
Ranges 2-3
= 0.4 ±1.45% of flow rate at 8:1 flow
turndown
±1.55% of flow rate at 8:1 flow
turndown
±1.40% of flow rate at 14:1 flow
turndown
= 0.65 ±1.45% of flow rate at 8:1 flow
turndown
±1.55% of flow rate at 8:1 flow
turndown
±1.40%of flow rate at 14:1 flow
turndown
Integral Orifice Flowmeter (3051SFP)
Ranges 2-3
< 0.1 ±2.65% of flow rate at 8:1 flow
turndown
±2.70% of flow rate at 8:1 flow
turndown
±2.60% of flow rate at 14:1 flow
turndown
0.1 < < 0.2 ±1.45% of flow rate at 8:1 flow
turndown
±1.60% of flow rate at 8:1 flow
turndown
±1.40% of flow rate at 14:1 flow
turndown
0.2 < < 0.6 ±1.05% of flow rate at 8:1 flow
turndown
±1.20% of flow rate at 8:1 flow
turndown
±0.95% of flow rate at 14:1 flow
turndown
0.6 < < 0.8 ±1.70% of flow rate at 8:1 flow
turndown
±1.80% of flow rate at 8:1 flow
turndown
±1.65% of flow rate at 14:1 flow
turndown
Models Ultra and Ultra for Flow
(1)
Classic and Classic MV
3051S_CD Ranges 2-5 ±0.20% of URL for 10 years; for ±50°F (28°C)
temperature changes, up to 1000 psi (68,9 bar)
line pressure
±0.125% of URL for 5 years; for ±50°F
(28°C) temperature changes, up to 1000 psi
(68,9 bar) line pressure
3051S_CG Ranges 2-5
3051S_CA Ranges 1-4
3051S_T Ranges 1-5
3051SMV
3051SF
DP Ranges 2-3
AP & GP Ranges 3-4
(1) Ultra is only available for 3051S, 3051SMV_ _3 and 4, 3051SF_3, 4, 7 and D. Ultra for Flow is only available on 3051S_CD ranges 2-3, 3051SMV DP
ranges 2-3, and 3051SF DP ranges 2-3.
Models
3051SMV
3051SF
RTD Interface
(1)
The greater of ±0.185°F (0.103°C) or 0.1% of reading per year (excludes RTD sensor stability).
(1) Specifications for process temperature are for the transmitter portion only. The transmitter is compatible with any Pt 100 (100 ohm platinum) RTD. Examples
of compatible RTDs include the Rosemount Series 68 and 78 RTD Temperature Sensors.